AC DC Converters
Explore AC DC Converters parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RST-15K-115AC/DC CONVERTER 115V 14.95KW |
3,713 |
|
Datasheet | RST-15K (15kW) | Box | Active | Enclosed | 1 | 196 ~ 305 VAC | 115V | - | - | - | - | - | 130 A | - | - | - | - | - | 14.95kW | ITE (Commercial) | 4.3 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off | Chassis Mount | 21.26" L x 16.69" W x 3.29" H (540.0mm x 424.0mm x 83.5mm) |
|
CF-02EM1982103POWER SUPPLY, SINGLE PHASE AC, 2 |
2,407 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CF-02EM1982104POWER SUPPLY, SINGLE PHASE AC, 2 |
1,470 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SHP-30K-230O/P +230V130.5A |
2,243 |
|
Datasheet | SHP-30K-HV (30kW) | Bulk | Active | Enclosed | 1 | 340 ~ 530 VAC (3 Phase) | 230V | - | - | - | - | - | 130.5 A | - | - | - | - | - | 30kW | ITE (Commercial) | 4.25 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Standby Output | Chassis Mount | 21.26" L x 16.69" W x 3.29" H (540.0mm x 424.0mm x 83.5mm) |
|
SHP-30K-115O/P +115V261A |
3,074 |
|
Datasheet | SHP-30K-HV (30kW) | Bulk | Active | Enclosed | 1 | 340 ~ 530 VAC (3 Phase) | 115V | - | - | - | - | - | 261 A | - | - | - | - | - | 30kW | ITE (Commercial) | 4.25 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Standby Output | Chassis Mount | 21.26" L x 16.69" W x 3.29" H (540.0mm x 424.0mm x 83.5mm) |
|
SHP-30K-055O/P +55V346A |
3,642 |
|
Datasheet | SHP-30K-HV (30kW) | Bulk | Active | Enclosed | 1 | 340 ~ 530 VAC (3 Phase) | 55V | - | - | - | - | - | 346 A | - | - | - | - | - | 20kW | ITE (Commercial) | 4.25 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Standby Output | Chassis Mount | 21.26" L x 16.69" W x 3.29" H (540.0mm x 424.0mm x 83.5mm) |
|
SHP-30K-380O/P +380V79A |
3,989 |
|
Datasheet | SHP-30K-HV (30kW) | Bulk | Active | Enclosed | 1 | 340 ~ 530 VAC (3 Phase) | 380V | - | - | - | - | - | 79 A | - | - | - | - | - | 30kW | ITE (Commercial) | 4.25 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Standby Output | Chassis Mount | 21.26" L x 16.69" W x 3.29" H (540.0mm x 424.0mm x 83.5mm) |
|
CF-02EM186103POWER SUPPLY, 3-PHASE AC, 28V DC |
3,129 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TPF45000-385AC/DC CONVERTER 385V 42000W |
2,238 |
|
Datasheet | TPF45000-385 (45W) | Box | Active | Enclosed | 1 | 360 ~ 528 VAC (3 Phase) | 385V | - | - | - | - | - | 110 A | - | - | - | - | - | 42000W | ITE (Commercial) | - | -10°C ~ 50°C | PMBus™, Remote On/Off, Standby Output | Chassis Mount | 21.00" L x 17.70" W x 4.40" H (533.4mm x 449.6mm x 111.8mm) |
|
VGSM-250C-12AC-DC, 250 W, 12 VDC, SINGLE OUT |
1,275 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W | Medical | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 1.57" H (121.7mm x 63.0mm x 39.9mm) |
|
VGS-250C-24-CFAC-DC, 250 W, 24 VDC, SINGLE OUT |
1,166 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (250W Forced Air) | ITE (Commercial) | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 2.00" H (121.7mm x 63.0mm x 50.8mm) |
|
VGSM-250C-12-CFAC-DC, 250 W, 12 VDC, SINGLE OUT |
1,005 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W (250W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 2.00" H (121.7mm x 63.0mm x 50.8mm) |
|
VGSM-250C-24AC-DC, 250 W, 24 VDC, SINGLE OUT |
4,527 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W | Medical | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 1.57" H (121.7mm x 63.0mm x 39.9mm) |
|
VGS-250C-12-CFAC-DC, 250 W, 12 VDC, SINGLE OUT |
2,620 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W (250W Forced Air) | ITE (Commercial) | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 2.00" H (121.7mm x 63.0mm x 50.8mm) |
|
VGS-250C-12AC-DC, 250 W, 12 VDC, SINGLE OUT |
2,520 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W | ITE (Commercial) | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 1.57" H (121.7mm x 63.0mm x 39.9mm) |
|
VGSM-250C-24-CFAC-DC, 250 W, 24 VDC, SINGLE OUT |
3,740 |
|
Datasheet | * | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (250W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 4.79" L x 2.48" W x 2.00" H (121.7mm x 63.0mm x 50.8mm) |
|
CHB200W12-72S15N-CMFD+HDCHASSIS MOUNT, 200W, 12:1 14-160 |
4,803 |
|
Datasheet | - | Tray | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LFM200M280C-C0SWITCHING POWER SUPPLIES AC-DC S |
4,302 |
|
Datasheet | LFM200M (200W) | Tray | Active | Enclosed | 1 | 85 ~ 264 VAC, 115 ~ 370 VDC | 28V | - | - | - | - | - | 7.14 A | - | - | - | - | - | 170W (200W Forced Air) | Household Appliances, ITE (Commercial), Medical | 4.25 kV | -40°C ~ 80°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | Chassis Mount | 3.09" L x 2.28" W x 1.00" H (78.5mm x 57.9mm x 25.4mm) |
|
CFM500S280C-PM-RAC-DC MODULE CFM500S280C-PM-R WI |
2,100 |
|
Datasheet | CFM500S (500W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 28V | - | - | - | - | - | 17.86 A | - | - | - | - | - | 410W (500W Forced Air) | Household Appliances, ITE (Commercial) | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PFC, PMBUS™, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.35" L x 3.43" W x 1.67" H (136.0mm x 87.0mm x 42.5mm) |
|
CFM500S480-PM-RAC-DC MODULE CFM500S480-PM-R WI |
4,597 |
|
Datasheet | CFM500S (500W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 48V | - | - | - | - | - | 10.42 A | - | - | - | - | - | 380W (500W Forced Air) | Household Appliances, ITE (Commercial) | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, Baseplate, PFC, PMBus™, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.54" H (127.0mm x 81.4mm x 39.1mm) |
Frequently Asked Questions
What are AC DC Converters components used for?
AC DC Converters components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right AC DC Converters part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find AC DC Converters parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.