Power Entry Modules (PEM)
Explore Power Entry Modules (PEM) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Connector Style | Connector Type | Current Rating - Appliance Inlet | Voltage Rating - Appliance Inlet | Number of Positions | Filter Type | Current Rating - Filter | Switch Features | Current Rating - Circuit Breaker | Accomodates a Fuse | Mounting Type | Termination | Features | Fuse Holder, Drawer | Panel Cutout Dimensions | Panel Thickness | Material Flammability Rating | Ingress Protection |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN9222R-15-07HIPWR ENT RCPT IEC320-C16 PNL WIRE |
0 |
|
Datasheet | FN 9222 | Tray | Active | IEC 320-C16 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 15A | - | - | No | Panel Mount, Flange | Wire Leads | Bleed Resistor, Front or Rear Side Mount | - | Rectangular - 28.50mm x 21.50mm | - | UL94 V-2 | IP40 |
|
FN9222ESB-10-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9222E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial, Medical | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Bleed Resistor, Earth Line Choke | - | Rectangular - 29.40mm x 20.80mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
FN9222ES1B-10-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9222E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial, Medical | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Bleed Resistor, Earth Line Choke | - | Rectangular - 28.50mm x 21.90mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
FN9233S1R-15-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9233 | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 15A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Bleed Resistor | - | Rectangular - 28.50mm x 21.90mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
10GENG3E-RPWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 10A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect | Bleed Resistor | - | Rectangular - 28.45mm x 21.90mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
FN9222E-6-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9222E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 6A | - | - | No | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Earth Line Choke, Front or Rear Side Mount | - | Rectangular - 28.50mm x 21.50mm | - | UL94 V-2 | IP40 |
|
FN9244SR-6-07PWR ENT RCPT IEC320-C14 PANEL |
0 |
|
Datasheet | FN 9244 | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 7.2A | - | - | No | Panel Mount, Snap-In | - | - | - | Rectangular - 29.40mm x 20.80mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
FN9244ES-1-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9244E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 1A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Earth Line Choke | - | Rectangular - 29.40mm x 20.80mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
15GEEW3E-RPWR ENT RCPT IEC320-C14 PNL WIRE |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 15A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 15A | - | - | No | Panel Mount, Flange | Wire Leads | Bleed Resistor | - | Rectangular - 28.45mm x 21.60mm | - | - | - |
|
06GKNG3EPWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | GKN | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 6A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 6A | - | - | No | Panel Mount, Snap-In | Quick Connect | - | - | Rectangular - 28.45mm x 21.90mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
10GEEW3E-RPWR ENT RCPT IEC320-C14 PNL WIRE |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 10A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 10A | - | - | No | Panel Mount, Flange | Wire Leads | Bleed Resistor | - | Rectangular - 28.45mm x 21.60mm | - | - | - |
|
10GENG3EM-RPWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 10A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect | Bleed Resistor | - | Rectangular - 28.45mm x 21.90mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
10GENG3QM-R(H)PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 10A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect | Bleed Resistor, Mounting Clip | - | Rectangular - 29.50mm x 21.50mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
08KENG3EAM-RPWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | KEN | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 8A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 8A | - | - | No | Panel Mount, Snap-In | Quick Connect | Bleed Resistor | - | Rectangular - 28.45mm x 21.90mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
10KENG3EAM-RPWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | KEN | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | 10A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 10A | - | - | No | Panel Mount, Snap-In | Quick Connect | Bleed Resistor | - | Rectangular - 28.45mm x 21.90mm | 0.032" ~ 0.063" (0.81mm ~ 1.60mm) | - | - |
|
03GEEW3VHP IEC CONNECTOR FILTER 3A |
0 |
|
Datasheet | GE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 3A | No Breaker/Switch | - | No | Panel Mount, Flange, Right Angle | Wire Leads | - | - | Rectangular - 30.50mm x 22.90mm | - | - | - |
|
FN9222ES1B-12-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9222E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial, Medical | 12A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Bleed Resistor, Earth Line Choke | - | Rectangular - 28.50mm x 21.90mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
04BEEG3SPWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | BE | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 4A | 115/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 4A | - | - | Yes (Fuse Not Included) | Panel Mount, Flange | Quick Connect | - | Fuse Holder | Rectangular - 29.00mm x 33.00mm | - | - | - |
|
FN9244ES1-1-06PWR ENT RCPT IEC320-C14 PANEL QC |
0 |
|
Datasheet | FN 9244E | Tray | Active | IEC 320-C14 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 1A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Earth Line Choke | - | Rectangular - 28.50mm x 21.90mm | 0.028" ~ 0.059" (0.70mm ~ 1.50mm) | UL94 V-2 | IP40 |
|
4301.3333PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | KEA-Print | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 10A | 250VAC | 3 | Unfiltered - Commercial | - | - | - | Yes (Fuse Not Included) | Panel Mount, Snap-In; Through Hole, Right Angle | Solder | - | Fuse Holder | Rectangular - 27.60mm x 31.60mm | 0.315" (8.00mm) | UL94 V-0 | IP40 |
Frequently Asked Questions
What are Power Entry Modules (PEM) components used for?
Power Entry Modules (PEM) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Entry Modules (PEM) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Entry Modules (PEM) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.