Power Entry Modules (PEM)
Explore Power Entry Modules (PEM) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Connector Style | Connector Type | Current Rating - Appliance Inlet | Voltage Rating - Appliance Inlet | Number of Positions | Filter Type | Current Rating - Filter | Switch Features | Current Rating - Circuit Breaker | Accomodates a Fuse | Mounting Type | Termination | Features | Fuse Holder, Drawer | Panel Cutout Dimensions | Panel Thickness | Material Flammability Rating | Ingress Protection |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EF11.2145.0014.01EF11 POWER ENTRY MODULE 16A C20 |
0 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
3-137-097EF11 POWER ENTRY MODULE 16A C20 |
0 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
PS000SM3EPWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | P, Corcom | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 3A | 120/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 3A | - | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Quick Connect - 0.187" (4.7mm) | Conversion Clip, Shielded | Fuse Holder | Variable Size | 0.031" ~ 0.114" (0.79mm ~ 2.90mm) | - | - |
|
PS000DM3EPWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | P, Corcom | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 3A | 120/250VAC | 3 | Filtered (EMI, RFI) - Commercial | 3A | - | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Quick Connect - 0.187" (4.7mm) | Shielded | Fuse Holder, Twin Fused | Variable Size | 0.031" ~ 0.114" (0.79mm ~ 2.90mm) | - | - |
|
4301.6013.01PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | KFA | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 4A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial | 4A | - | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | Drawer Included | Rectangular - 30.30mm x 34.30mm | 0.031" ~ 0.118" (0.79mm ~ 3.00mm) | UL94 V-0 | IP40 |
|
1-6609106-3PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | P, Corcom | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 3A | 120VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 3A | Switch On-Off | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Quick Connect - 0.187" (4.7mm) | Conversion Clip, Voltage Selector | Fuse Holder | Variable Size | 0.031" ~ 0.114" (0.79mm ~ 2.90mm) | - | - |
|
F3300WA03PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | F3300 | Box | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 3A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 3A | - | - | Yes (Fuse Not Included) | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | - | Fuse Holder, Twin Fused | Rectangular - 29.08mm x 32.39mm | - | - | - |
|
6431.0053.12PWR ENT IN/OUT IEC320-2-2F PNL |
0 |
|
Datasheet | FELCOM 64 | Bulk | Obsolete | IEC 320-2-2/F; IEC 320-C14 | Receptacle, Female Sockets; Receptacle, Male Blades | 10A | 250VAC | 3 per connection (2) | Unfiltered - Commercial | - | Switch On-Off | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | - | - | Rectangular - 27.60mm x 80.10mm | 0.047" (1.20mm) | UL94 V-0 | - |
|
FN9299-1-100PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | FN 9290 | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | - | - | 3 | Filtered (EMI, RFI) - Commercial | 1A | Switch On-Off | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Spring-Cage | - | Fuse Holder, Twin Fused | Rectangular - 28.80mm x 47.80mm | 0.039" ~ 0.098" (1.00mm ~ 2.50mm) | UL94 V-2 | IP40 |
|
KMF1.1193.1103KMF CONNECTOR FILTER C14 10A M5 |
0 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FN9289E-6-100PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | FN 9280 | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | - | - | 3 | Filtered (EMI, RFI) - Commercial, Medical | 6A | Switch On-Off | - | Yes (Fuse Not Included) | Panel Mount, Snap-In | Spring-Cage | - | Fuse Holder, Twin Fused | Rectangular - 28.80mm x 47.80mm | 0.039" ~ 0.098" (1.00mm ~ 2.50mm) | UL94 V-2 | IP40 |
|
FN9255R-20-07PWR ENT RCPT IEC320-C20 PNL WIRE |
0 |
|
Datasheet | FN 9255 | Bulk | Last Time Buy | IEC 320-C20 | Receptacle, Male Blades | - | - | 3 | Filtered (EMI, RFI) - Commercial | 20A | - | - | No | Panel Mount, Flange | Wire Leads | Front Side Mount | - | Rectangular - 34.90mm x 27.10mm | - | UL94 V-0 | IP40 |
|
C20F.0121PWR ENT RCPT IEC320-C20 PANEL QC |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial | 16/20A | - | - | No | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Shielded | - | Rectangular - 36.40mm x 28.30mm | - | UL94 V-0 | IP40 |
|
C20F.0012PWR ENT RCPT IEC320-C20 PNL SLDR |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 16/20A | - | - | No | Panel Mount, Snap-In | Solder Eyelet | Shielded | - | Rectangular - 34.80mm x 26.30mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 |
|
C20F.0112PWR ENT RCPT IEC320-C20 PANEL QC |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 16/20A | - | - | No | Panel Mount, Snap-In | Quick Connect - 0.250" (6.3mm) | Shielded | - | Rectangular - 34.80mm x 26.30mm | 0.039" ~ 0.118" (1.00mm ~ 3.00mm) | UL94 V-0 | IP40 |
|
C20F.0021PWR ENT RCPT IEC320-C20 PNL SLDR |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial | 20A | - | - | No | Panel Mount, Flange | Solder Eyelet | Shielded | - | Rectangular - 36.40mm x 28.30mm | - | UL94 V-0 | IP40 |
|
C20F.0022PWR ENT RCPT IEC320-C20 PNL SLDR |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 16/20A | - | - | No | Panel Mount, Flange | Solder Eyelet | Shielded | - | Rectangular - 36.40mm x 28.30mm | - | UL94 V-0 | IP40 |
|
C20F.0122PWR ENT RCPT IEC320-C20 PANEL QC |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 16/20A | - | - | No | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Shielded | - | Rectangular - 36.40mm x 28.30mm | - | UL94 V-0 | IP40 |
|
C20F.0125PWR ENT RCPT IEC320-C20 PANEL QC |
0 |
|
Datasheet | C20F | Bulk | Active | IEC 320-C20 | Receptacle, Male Blades | 16A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial, Medical | 16/20A | - | - | No | Panel Mount, Flange | Quick Connect - 0.250" (6.3mm) | Shielded | - | Rectangular - 36.40mm x 28.30mm | - | UL94 V-0 | IP40 |
|
4303.5002PWR ENT MOD RCPT IEC320-C14 PNL |
0 |
|
Datasheet | KFC | Bulk | Active | IEC 320-C14 | Receptacle, Male Blades - Module | 2A | 250VAC | 3 | Filtered (EMI, RFI) - Commercial | 2A | - | - | Yes (Fuse Not Included) | Panel Mount, Flange | Quick Connect - 0.189" (4.8mm) | - | Drawer Sold Separate | Rectangular - 28.60mm x 50.00mm | - | UL94 V-0 | IP40 |
Frequently Asked Questions
What are Power Entry Modules (PEM) components used for?
Power Entry Modules (PEM) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Entry Modules (PEM) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Entry Modules (PEM) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.