| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output Type | Control Method | Communications | Number of Characters Per Row | Display Type | Display Characters - Height | Voltage - Supply | Panel Cutout Dimensions | Mounting Type | Termination Style | Ingress Protection | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
THYRO-A 3A 400-280 HF3THYRO-A 3A 400-280 HF3 |
1,684 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 400-1500 HFRL3THYRO-A 1A 400-1500 HFRL3 |
4,465 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 1500A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-PX 2PX 690-80 HTHYRO-PX 2PX 690-80 H |
4,272 |
|
Datasheet | Thyro-PX® | Box | Active | Power Controller | 16 ~ 80A, 400 ~ 759VAC | Analog (3) | On/Off, Phase Control | USB | - | - | - | 90 ~ 265VAC, 21.6 ~ 26.4VDC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 500-130 HRL3THYRO-A 3A 500-130 HRL3 |
2,966 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 130A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-S 3S 500-350 HF3THYRO-S 3S 500-350 HF3 |
1,015 |
|
Datasheet | Thyro-S® | Box | Active | Power Controller | 8 ~ 350A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-PX 1PX 690-200 HFTHYRO-PX 1PX 690-200 HF |
3,176 |
|
Datasheet | Thyro-PX® | Box | Active | Power Controller | 16 ~ 200A, 400 ~ 759VAC | Analog (3) | On/Off, Phase Control | USB | - | - | - | 90 ~ 265VAC, 21.6 ~ 26.4VDC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
E5ZE-8AQHD1PB-V2 DC24CONTROL TEMP SS/VOLT OUT 24V |
3,838 |
|
Datasheet | E5ZE | Bulk | Obsolete | Temperature Controller (RTD) | -100°C ~ 500°C | Solid State (3), Voltage (External SSR) | On/Off, Proportional (PID) | DeviceNet | - | - | - | 24VDC | - | Chassis Mount | Screw Terminal | IP00 | Heater Fault Detection, Sensor Fault Detection |
|
E5ZE-8AQHD1TCB-V2 DC24CONTROL TEMP SS/VOLT OUT 24V |
4,662 |
|
Datasheet | E5ZE | Bulk | Obsolete | Temperature Controller (Type B, E, J, K, L, N, PLII, R, S, T, U, W) | -200°C ~ 2300°C | Solid State (3), Voltage (External SSR) | On/Off, Proportional (PID) | DeviceNet | - | - | - | 24VDC | - | Chassis Mount | Screw Terminal | IP00 | Heater Fault Detection, Sensor Fault Detection |
|
THYRO-A 2A 500-350 HFRL3THYRO-A 2A 500-350 HFRL3 |
2,796 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 350A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-S 3S 400-350 HF RLP3THYRO-S 3S 400-350 HF RLP3 |
2,994 |
|
Datasheet | Thyro-S® | Box | Active | Power Controller | 8 ~ 350A, 340 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A+ 2A 500-280 HF RLP 4THYRO-A+ 2A 500-280 HF RLP 4 |
1,582 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 400-130 HRLP3THYRO-A 3A 400-130 HRLP3 |
1,928 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 130A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
E5AR-TCCE3MWW-FLK AC100-240CONTROL TEMP/PROCESS 100-240V |
3,895 |
|
Datasheet | E5AR-T | Bulk | Obsolete | Process, Temperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U, W) | -200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC | Analog (4), Solid State (10) | On/Off, Proportional (PID) | RS-485 (CompoWay/F) | 5, 5, 4 | LCD - Tri Color Characters, Backlight | 0.504" (12.80mm), 0.303" (7.70mm), 0.303" (7.70mm) | 100 ~ 240VAC | Square - 92.00mm x 92.00mm | Panel Mount | Screw Terminal | IP66 - Dust Tight, Water Resistant | - |
|
THYRO-S 3S 500-280 HF RLP3THYRO-S 3S 500-280 HF RLP3 |
4,692 |
|
Datasheet | Thyro-S® | Box | Active | Power Controller | 8 ~ 280A, 425 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 500-100 HRLP3THYRO-A 3A 500-100 HRLP3 |
2,774 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 100A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 2A 500-280 HFRLP3THYRO-A 2A 500-280 HFRLP3 |
2,794 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A+ 3A 500-170 H RL 4THYRO-A+ 3A 500-170 H RL 4 |
4,648 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 170A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
E5ZE-8VQHD1TCB-V2 DC24CONTROL TEMP SS/VOLT OUT 24V |
1,858 |
|
Datasheet | E5ZE | Bulk | Obsolete | Temperature Controller (Type B, E, J, K, L, N, PLII, R, S, T, U, W) | -200°C ~ 2300°C | Solid State (3), Voltage (External SSR) | On/Off, Proportional (PID) | DeviceNet | - | - | - | 24VDC | - | Chassis Mount | Screw Terminal | IP00 | Heater Fault Detection, Sensor Fault Detection |
|
THYRO-A 2A 400-350 HFRLP3THYRO-A 2A 400-350 HFRLP3 |
2,347 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 350A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 500-1000 HFRLP3THYRO-A 1A 500-1000 HFRLP3 |
1,160 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 1000A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
Frequently Asked Questions
What are Process, Temperature components used for?
Process, Temperature components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Process, Temperature part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Process, Temperature parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.