DC Brushless Fans (BLDC)
Explore DC Brushless Fans (BLDC) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
109E1324S101FAN AXIAL 127X38MM 24VDC WIRE |
3,321 |
|
Datasheet | San Ace 127 | Box | Active | 24VDC | Square - 127mm L x 127mm H | 38.00mm | 154.0 CFM (4.31m³/min) | 0.502 in H2O (125.0 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 49.0dB(A) | 12.7 W | 3450 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.882 lb (400.07 g) |
|
9LG1424A5D001FAN AXIAL 140X51MM 24VDC WIRE |
1,388 |
|
Datasheet | San Ace 140L | Box | Active | 24VDC | Square - 140mm L x 140mm H | 51.00mm | 243.7 CFM (6.82m³/min) | 2.170 in H2O (540.5 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | - | 29.1 W | 5700 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.8 lb (800.0 g) |
|
109E1724K501FAN AXIAL 172X51MM 24VDC WIRE |
1,351 |
|
Datasheet | San Ace 172 | Box | Active | 24VDC | Round - 172mm Dia | 51.00mm | 300.0 CFM (8.40m³/min) | 0.976 in H2O (243.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 55.0dB(A) | 31.2 W | 4100 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.7 lbs (780.0 g) |
|
109E5712K501FAN AXIAL 172X51MM 12VDC WIRE |
3,948 |
|
Datasheet | San Ace 172 | Box | Active | 12VDC | Rectangular/Rounded - 172mm L x 150mm H | 51.00mm | 300.0 CFM (8.40m³/min) | 0.976 in H2O (243.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 60.0dB(A) | 34.8 W | 4100 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 1.7 lbs (760.0 g) |
|
9LG1424P1M001FAN AXIAL 140X38MM 24VDC WIRE |
1,535 |
|
Datasheet | San Ace 140L | Bulk | Active | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 130.0 CFM (3.64m³/min) | 0.680 in H2O (169.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 46.0dB(A) | 7.2 W | 3300 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.4 lbs (650.0 g) |
|
9LG1412P1M001FAN AXIAL 140X38MM 12VDC WIRE |
3,173 |
|
Datasheet | San Ace 140L | Bulk | Active | 12VDC | Square - 140mm L x 140mm H | 38.00mm | 130.0 CFM (3.64m³/min) | 0.680 in H2O (169.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 46.0dB(A) | 7.2 W | 3300 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.4 lbs (650.0 g) |
|
9CRLA0612P0G001FAN AXIAL DUAL 60X76MM 12VDC |
1,648 |
|
Datasheet | San Ace 60L | Box | Active | 12VDC | Square - 60mm L x 60mm H | 76.00mm | 74.1 CFM (2.07m³/min) | 5.620 in H2O (1400.0 Pa) | Ball | Tubeaxial (Dual) | Counter-Rotating, Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 70.0dB(A) | 36 W | 16500 Front, 17800 Rear | 4 Wire Leads per Fan | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.684 lb (310.26 g) |
|
109E5724C502FAN AXIAL 172X51MM 24VDC WIRE |
3,242 |
|
Datasheet | San Ace 172 | Box | Active | 24VDC | Rectangular/Rounded - 172mm L x 150mm H | 51.00mm | 350.0 CFM (9.80m³/min) | 1.237 in H2O (308.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 66.0dB(A) | 55.2 W | 4800 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.7 lbs (760.0 g) |
|
109E1348G101FAN AXIAL 127X38MM 48VDC WIRE |
3,069 |
|
Datasheet | San Ace 127 | Box | Active | 48VDC | Square - 127mm L x 127mm H | 38.00mm | 200.0 CFM (5.60m³/min) | 0.867 in H2O (216.0 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 57.0dB(A) | 25.9 W | 4550 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.882 lb (400.07 g) |
|
9WL1424P1M001FAN AXIAL 140X38MM 24VDC WIRE |
1,175 |
|
Datasheet | San Ace 140W | Bulk | Active | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 130.0 CFM (3.64m³/min) | 0.680 in H2O (169.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 46.0dB(A) | 7.2 W | 3300 RPM | 4 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.653 lb (750.0 g) |
|
W2G107-AD03-02FAN AXIAL 119X38MM 24VDC TERM |
3,181 |
|
Datasheet | W2G107 | Bulk | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | - | - | Ball | Tubeaxial | Locked Rotor Protection | - | 3.3 W | 2800 RPM | 2 Terminals | IP22 | -13 ~ 162°F (-25 ~ 72°C) | EAC, UL | - |
|
9WL1448P1A001FAN AXIAL 140X38MM 48VDC WIRE |
2,854 |
|
Datasheet | San Ace 140W | Bulk | Active | 48VDC | Square - 140mm L x 140mm H | 38.00mm | 282.0 CFM (7.90m³/min) | 2.070 in H2O (515.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 68.0dB(A) | 44.16 W | 6900 RPM | 4 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.653 lb (750.0 g) |
|
OD180APL-24HBIP68FAN AXIAL 180X65MM 24VDC WIRE |
3,728 |
|
Datasheet | OD180APL-IP68 | Box | Active | 24VDC | Square - 180mm L x 180mm H | 65.00mm | 460.0 CFM (12.88m³/min) | 1.100 in H2O (274.0 Pa) | Ball | Tubeaxial | Auto Restart | 63.2dB(A) | 60.2 W | 3375 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 149°F (-20 ~ 65°C) | CE, cURus, TUV, UR | - |
|
OD180APL-12HBIP69KFAN AXIAL 180X65MM 12VDC WIRE |
1,433 |
|
Datasheet | OD180APL-IP69K | Box | Active | 12VDC | Square - 180mm L x 180mm H | 65.00mm | 460.0 CFM (12.88m³/min) | 1.100 in H2O (274.0 Pa) | Ball | Tubeaxial | Auto Restart | 63.2dB(A) | 50.4 W | 3375 RPM | 2 Wire Leads | IP69K - Dust Tight, Water Resistant, Waterproof | -4 ~ 149°F (-20 ~ 65°C) | CE, cURus, TUV, UR | - |
|
OD254AP-12HBFAN AXIAL 254X89MM 12VDC WIRE |
1,039 |
|
Datasheet | OD254 | Box | Active | 12VDC | Round - 254mm Dia | 89.00mm | 830.0 CFM (23.24m³/min) | 0.780 in H2O (194.3 Pa) | Ball | Tubeaxial | Auto Restart | 60.0dB | 65 W | 2400 RPM | 2 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | cURus, TUV | - |
|
OD254AP-48HB10AFAN AXIAL 254X89MM 48VDC WIRE |
2,352 |
|
Datasheet | OD254 | Bulk | Active | 48VDC | Round - 254mm Dia | 89.00mm | 850.0 CFM (23.80m³/min) | 0.830 in H2O (206.7 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 64.0dB | 62 W | 2500 RPM | 4 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | cURus, TUV | - |
|
OD254AP-12HB10AFAN AXIAL 254X89MM 12VDC WIRE |
2,086 |
|
Datasheet | OD254 | Bulk | Active | 12VDC | Round - 254mm Dia | 89.00mm | 830.0 CFM (23.24m³/min) | 0.780 in H2O (194.3 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 60.0dB | 65 W | 2400 RPM | 4 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | cURus, TUV | - |
|
9W2TN24P1H001FAN IMP MTRZD 150X35MM 24VDC |
1,717 |
|
Datasheet | San Ace 150W | Box | Active | 24VDC | Round - 150mm Dia | 35.00mm | 135.0 CFM (3.78m³/min) | 1.578 in H2O (393.1 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 59.0dB(A) | 15.4 W | 3800 RPM | 4 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.86 lb (390.09 g) |
|
OD254AP-24HBIP68FAN IMP MTRZD 254X89MM 24VDC |
3,335 |
|
Datasheet | OD254AP-IP68 | Box | Active | 24VDC | Round - 254mm Dia | 89.00mm | 830.0 CFM (23.24m³/min) | 0.790 in H2O (196.8 Pa) | Ball | Motorized Impellers | Auto Restart | 62.1dB(A) | 65 W | 2450 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 149°F (-20 ~ 65°C) | CE, cURus, TUV, UR | - |
|
MSI2577H24B1+7-BBRFAN IMP MTRZD 250X77.3MM 24VDC |
3,094 |
|
Datasheet | MSI2577 | Box | Active | 24VDC | Round - 250mm Dia | 77.30mm | 716.0 CFM (20.05m³/min) | 3.365 in H2O (838.2 Pa) | Ball | Motorized Impellers | Auto Restart, Speed Sensor (Tach), Voltage Control | 76.0dB(A) | - | 2800 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL | 4.5 lbs (2 kg) |
Frequently Asked Questions
What are DC Brushless Fans (BLDC) components used for?
DC Brushless Fans (BLDC) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right DC Brushless Fans (BLDC) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find DC Brushless Fans (BLDC) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.