DC Brushless Fans (BLDC)
Explore DC Brushless Fans (BLDC) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
9GA0624P1K03FAN AXIAL 60X38MM 24VDC WIRE |
3,312 |
|
Datasheet | San Ace 60 | Box | Active | 24VDC | Square - 60mm L x 60mm H | 38.00mm | 53.0 CFM (1.48m³/min) | 2.400 in H2O (597.8 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 59.0dB(A) | 12 W | 14800 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.287 lb (130.18 g) |
|
|
9GA0912P4S03FAN AXIAL 92X25MM 12VDC WIRE |
4,945 |
|
Datasheet | San Ace 92 | Box | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 59.0 CFM (1.65m³/min) | 0.240 in H2O (59.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 35.0dB(A) | 2.4 W | 3800 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.276 lb (125.19 g) |
|
|
9GA0912P4G03FAN AXIAL 92X25MM 12VDC WIRE |
3,778 |
|
Datasheet | San Ace 92 | Box | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 68.1 CFM (1.91m³/min) | 0.326 in H2O (81.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 39.0dB(A) | 3.36 W | 4400 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.276 lb (125.19 g) |
|
|
9G0624P4S001FAN AXIAL 60X25MM 24VDC WIRE |
3,827 |
|
Datasheet | San Ace 60 | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 49.4 CFM (1.38m³/min) | 1.200 in H2O (298.9 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 53.0dB(A) | 8.16 W | 11000 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.199 lb (90.26 g) |
|
|
AFB1224SHE-T50FFAN AXIAL 120X38MM 24VDC WIRE |
3,301 |
|
Datasheet | AFB | Bulk | Active | 24VDC | Square - 120mm L x 120mm H | 38.00mm | 151.9 CFM (4.25m³/min) | 0.571 in H2O (142.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 53.0dB(A) | 12 W | 3700 RPM | 3 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 140°F (-10 ~ 60°C) | CE, CSA, UL, VDE | 0.565 lb (256.28 g) |
|
612NLEFAN AXIAL 60X25.4MM 12VDC WIRE |
4,024 |
|
Datasheet | 600N | Bulk | Active | 12VDC | Square - 60mm L x 60mm H | 25.40mm | 12.4 CFM (0.347m³/min) | - | Ball | Tubeaxial | - | 16.0dB(A) | 400 mW | 2500 RPM | 2 Wire Leads | - | -4 ~ 185°F (-20 ~ 85°C) | CE, CSA, UL, VDE | 0.146 lb (66.22 g) |
|
9RA1212P4G001FAN AXIAL 120X25MM 12VDC WIRE |
1,215 |
|
Datasheet | San Ace 120 | Bulk | Active | 12VDC | Square - 120mm L x 120mm H | 25.00mm | 130.0 CFM (3.64m³/min) | 0.480 in H2O (119.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 47.0dB(A) | 6.6 W | 4500 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | - |
|
9L0412H301FAN AXIAL 40X28MM 12VDC WIRE |
1,007 |
|
Datasheet | San Ace 40L | Box | Active | 12VDC | Square - 40mm L x 40mm H | 28.00mm | 13.1 CFM (0.367m³/min) | 0.426 in H2O (106.1 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 40.0dB(A) | 1.8 W | 8400 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.122 lb (55.34 g) |
|
422JNFAN AXIAL 40X28MM 12VDC WIRE |
4,389 |
|
Datasheet | 420J | Bulk | Active | 12VDC | Square - 40mm L x 40mm H | 28.00mm | 18.3 CFM (0.512m³/min) | - | Ball | Tubeaxial | - | 48.0dB(A) | 4 W | 14000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, UL, VDE | 0.099 lb (44.91 g) |
|
|
9G0848G101FAN AXIAL 80X38MM 48VDC WIRE |
1,925 |
|
Datasheet | San Ace 80 | Box | Active | 48VDC | Square - 80mm L x 80mm H | 38.00mm | 90.0 CFM (2.52m³/min) | 0.847 in H2O (211.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 51.0dB(A) | 13 W | 6300 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.375 lb (170.1 g) |
|
9CRA0412P4K03FAN AXIAL DUAL 40X48MM 12VDC |
3,458 |
|
Datasheet | San Ace 40 | Box | Active | 12VDC | Square - 40mm L x 40mm H | 48.00mm | 32.5 CFM (0.910m³/min) | 2.610 in H2O (650.1 Pa) | Ball | Tubeaxial (Dual) | Counter-Rotating, Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 64.0dB(A) | 19.2 W | 17500 Front, 11700 Rear | 4 Wire Leads per Fan | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.176 lb (80.00 g) |
|
PFC0648SE-00P8FAN AXIAL 60X38MM 48VDC WIRE |
2,515 |
|
Datasheet | PFC | Box | Active | 48VDC | Square - 60mm L x 60mm H | 38.00mm | 65.3 CFM (1.83m³/min) | 3.503 in H2O (872.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 69.0dB(A) | 24.96 W | 17000 RPM | 4 Wire Leads | - | -13 ~ 158°F (-25 ~ 70°C) | CE, cURus, TUV | - |
|
9HVA0412P3J001FAN AXIAL 40X28MM 12VDC WIRE |
1,201 |
|
Datasheet | San Ace 40 | Bulk | Active | 12VDC | Square - 40mm L x 40mm H | 28.00mm | 37.1 CFM (1.04m³/min) | 9.240 in H2O (2300.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 71.0dB(A) | 31.2 W | 38000 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | - |
|
|
BCB1012UH-F00FAN BLOWER 97.2X25MM 12VDC WIRE |
1,462 |
|
Datasheet | BCB | Box | Active | 12VDC | Rectangular/Rounded - 97.2mm L x 94.4mm H | 25.00mm | 35.3 CFM (0.988m³/min) | 4.053 in H2O (1009.6 Pa) | Ball | Blower | Locked Rotor Protection, Speed Sensor (Tach) | 67.8dB(A) | 38.4 W | 9300 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CE, CSA, UL, VDE | 0.391 lb (177.35 g) |
|
|
9GA0812P1G61FAN AXIAL 80X38MM 12VDC WIRE |
2,705 |
|
Datasheet | San Ace 80 | Box | Active | 12VDC | Square - 80mm L x 80mm H | 38.00mm | 100.6 CFM (2.82m³/min) | 1.930 in H2O (480.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 60.0dB(A) | 14.4 W | 10500 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.353 lb (160.12 g) |
|
PFB0612EE-EFAN AXIAL 60X38MM 12VDC WIRE |
4,143 |
|
Datasheet | PFB | Box | Active | 12VDC | Square - 60mm L x 60mm H | 38.00mm | 77.0 CFM (2.16m³/min) | 7.310 in H2O (1820.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 68.6dB(A) | 42 W | 25500 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV | - |
|
414J/2HHFAN AXIAL 40X25.4MM 24VDC WIRE |
3,597 |
|
Datasheet | 400J | Bulk | Active | 24VDC | Square - 40mm L x 40mm H | 25.40mm | 14.1 CFM (0.395m³/min) | - | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 46.0dB(A) | 3.6 W | 13000 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | - | 0.111 lb (50.35 g) |
|
4414MFAN AXIAL 119X38MM 24VDC WIRE |
1,020 |
|
Datasheet | 4400 | Bulk | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 108.3 CFM (3.03m³/min) | - | Ball | Tubeaxial | Locked Rotor Protection | 42.0dB(A) | 4.1 W | 3300 RPM | 2 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | - | 0.553 lb (250.84 g) |
|
|
OD1238-24HBVXC10AFAN AXIAL 120X38MM 24VDC WIRE |
4,558 |
|
Datasheet | OD1238 VA | Box | Active | 24VDC | Square - 120mm L x 120mm H | 38.00mm | 226.0 CFM (6.33m³/min) | 1.350 in H2O (336.3 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 65.0dB | 40.8 W | 5000 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | cURus, TUV | - |
|
8218JNFAN AXIAL 80X38MM 48VDC WIRE |
4,050 |
|
Datasheet | 8200J | Bulk | Active | 48VDC | Square - 80mm L x 80mm H | 38.00mm | 78.0 CFM (2.18m³/min) | - | Ball | Tubeaxial | - | 55.0dB(A) | 11 W | 8400 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | - | 0.353 lb (160.12 g) |
Frequently Asked Questions
What are DC Brushless Fans (BLDC) components used for?
DC Brushless Fans (BLDC) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right DC Brushless Fans (BLDC) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find DC Brushless Fans (BLDC) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.