| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CN2-F60LINE FILTER 250VAC/VDC 6A CHASS |
3,092 |
|
Datasheet | CN | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FC-L04QBLINE FILTER 430VDC 230VAC 4A TH |
2,245 |
|
Datasheet | FC-LxxQB | Tray | Not For New Designs | Single Phase | Single Stage | 430V | 230V | 4 kV | 2 kV | 4 A | 50 ~ 60Hz | General Purpose | CE, UKCA | -40°C ~ 105°C | Through Hole | PC Pins | - |
|
EMC-05ALINE FILTER 85V-305VAC 0.5A TH |
3,226 |
|
Datasheet | - | Tray | Not For New Designs | Single Phase | Single Stage | - | 85V ~ 305V | - | - | 500 mA | 47Hz, 63Hz | General Purpose | - | -40°C ~ 85°C | Through Hole | PC Pins | - |
|
VFM-03-DLINE FILTER 80VDC 3A TH |
3,499 |
|
Datasheet | VFM-03 | Tube | Not For New Designs | DC | Single Stage | 80V | - | - | - | 3 A | - | General Purpose | - | -40°C ~ 85°C | Through Hole | PC Pins | - |
|
CA5-W43LINE FILTER 250VAC/VDC 5A CHASS |
3,165 |
|
Datasheet | CA5 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 5 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Wire Leads | - |
|
CA5-V23LINE FILTER 250VAC/VDC 1.5A CHAS |
2,731 |
|
Datasheet | CA5 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 1.5 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Wire Leads | - |
|
CA5-V33LINE FILTER 250VAC/VDC 3A CHASS |
3,643 |
|
Datasheet | CA5 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Wire Leads | - |
|
5003.025B.1LINE FILTER 125VDC 6A PANEL MNT |
3,164 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 6 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | PC Pins | 800µH |
|
5003.016B.1LINE FILTER 125VDC 3A PANEL MNT |
1,672 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 3 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | PC Pins | 4mH |
|
AMI-M11A-1-10-BLINE FILTER 250VAC 10A CHASS MNT |
4,479 |
|
Datasheet | AMI-M11A | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 495µH |
|
|
5003.0111.1LINE FILTER 125VDC 3A PANEL MNT |
4,437 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 3 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 4mH |
|
5003.0211.1LINE FILTER 125VDC 6A PANEL MNT |
2,890 |
|
Datasheet | 5003 | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
5003.0221.1LINE FILTER 125VDC 6A PANEL MNT |
3,956 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 6 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 800µH |
|
5003.0411.1LINE FILTER 125VDC 15A PANEL MNT |
2,109 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 15 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 100µH |
|
|
5003.0431.1LINE FILTER 125VDC PANEL MOUNT |
3,221 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | - | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | - | - |
|
5003.0321.1LINE FILTER 125VDC 10A PANEL MNT |
2,725 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 10 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 400µH |
|
5003.1336.1LINE FILTER 125VDC 10A PANEL MNT |
1,615 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 10 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Wire Leads | 400µH |
|
FC-L03WLINE FILTER 430VDC 230VAC 3A DIN |
4,173 |
|
Datasheet | FC-L03Wx | Box | Not For New Designs | Single Phase | Single Stage | 430V | 230V | 4 kV | 2 kV | 3 A | 50 ~ 60Hz | General Purpose | CE, UKCA | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
IR-0622HLINE FLTR 250VAC/VDC 6A PANEL |
2,201 |
|
Datasheet | IR | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
5003.1211.1LINE FILTER 125VDC 6A PANEL MNT |
1,679 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 6 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 800µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.