Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
FN3270H-80-35LINE FILTER 480VAC 80A CHASS MNT |
4,222 |
|
Datasheet | FN 3270 | Tray | Active | Three Phase (Delta) | Single Stage | - | 480V | 300 V | 520 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2220-600-99-C2222-R99LINE FLTR 1000VDC 600A CHASS MNT |
3,782 |
|
Datasheet | FN2220 | Bulk | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 600 A | DC | General Purpose | CE, CSA, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M10) | - |
|
FN2200-250-99LINE FLTR 1200VDC 250A CHASS MNT |
1,948 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 250 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
MRI43100WLINE FILTER 60VDC 3A CHASS MNT |
1,246 |
|
Datasheet | - | Box | Active | DC | Single Stage | 60V | - | - | - | 3 A | - | Medical | - | -10°C ~ 60°C | Chassis Mount | Wire Leads | - |
|
FN3270H-200-99LINE FILTER 200A CHASSIS MOUNT |
1,882 |
|
Datasheet | FN 3270 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 200 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143B0320S020LINE FILTER 530/310VAC 320A CHAS |
4,675 |
|
Datasheet | B84143B | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 310V | - | - | 320 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
FN3270H-320-99LINE FILTER 320A CHASSIS MOUNT |
4,728 |
|
Datasheet | FN 3270 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 320 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359-250-28LINE FILTER 250A CHASSIS MOUNT |
4,618 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 250 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
FN3359-320-99LINE FILTER 320A CHASSIS MOUNT |
3,905 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 320 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
5500.2002LINE FILTER 125V/250VAC 2A TH |
4,670 |
|
Datasheet | FPP-01 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 2 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 4mH |
|
|
2-6609089-4LINE FILTER 250VAC 16A CHASS MNT |
2,635 |
|
Datasheet | WG | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect, Threaded Post (M8) | 540µH |
|
|
FN402-4-02LINE FILTER 250VAC 4A TH |
2,166 |
|
Datasheet | FN 402 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 4 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 1mH |
|
FHSMM01A1FRLINE FILTER 250VAC 1A CHASS MNT |
1,924 |
|
Datasheet | - | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Medical | EN, UL | -40°C ~ 110°C | Chassis Mount | Quick Connect | 10mH |
|
2VB1LINE FILTER 250VAC 2A CHASS MNT |
2,124 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 2 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 539µH |
|
|
5VK1LINE FILTER 250VAC 5A CHASS MNT |
3,850 |
|
Datasheet | K | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 5 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 516µH |
|
|
16DBCG5BLINE FILTER 115V/250VAC 16A CHAS |
3,878 |
|
Datasheet | DB | Box | Active | Single Phase | Single Stage | - | 115V, 250V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 650µH |
|
|
B84111F0000B030LINE FILTER 250VAC/VDC 3A CHASS |
2,842 |
|
Datasheet | B84111F | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
FM10-100LINE FILTER 75VDC 10A TH |
1,575 |
|
Datasheet | FM | Tube | Active | Single Phase | Single Stage | 75V | - | - | - | 10 A | - | General Purpose | - | -40°C ~ 100°C | Through Hole | PC Pins | - |
|
FPBB-U3RI-1090LINE FILTER 250VAC/VDC 10A DIN |
4,059 |
|
Datasheet | FPBB RAIL | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
|
B84112G0000B110LINE FILTER 250VAC/VDC 10A CHASS |
2,348 |
|
Datasheet | B84112G | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.8mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.