| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMAD-0954-H110LINE FILTER 277/480VAC 110A CHAS |
3,561 |
|
Datasheet | FMAD | Bag | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 110 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 500µH |
|
150 AHV S BSLINE FILTER 150A CHASSIS MOUNT |
1,915 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 150 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBC-A91V-J810LINE FILTER 480/520VAC 180A CHAS |
2,960 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 180 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 400µH, L2 - 31µH |
|
FN3311-1000-99-C16-R55LINE FILTER 520V/300VAC 1KA CHAS |
2,881 |
|
Datasheet | FN 3311 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300 V | 520 V | 1 kA | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
400 AHV S FPLINE FILTER 400A CHASSIS MOUNT |
3,661 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 400 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
500 AHV S FPLINE FILTER 500A CHASSIS MOUNT |
4,661 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 500 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
600 AHV S FPLINE FILTER 600A CHASSIS MOUNT |
3,324 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 600 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
400 AHV D FPLINE FILTER 400A CHASSIS MOUNT |
1,639 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 400 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
B84143B1000S020LINE FILTER 530V/310VAC 1KA CHAS |
1,224 |
|
Datasheet | B84143B | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 310V | - | - | 1 kA | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Block, Threaded Post (M12) | - |
|
500 AHV D FPLINE FILTER 500A CHASSIS MOUNT |
4,203 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 500 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
600 AHV D FPLINE FILTER 600A CHASSIS MOUNT |
4,343 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 600 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
700 AHV S FPLINE FILTER 700A CHASSIS MOUNT |
4,105 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 700 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
800 AHV S FPLINE FILTER 800A CHASSIS MOUNT |
2,496 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 800 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
1000 AHV S FPLINE FILTER 1KA CHASSIS MOUNT |
3,166 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 1 kA | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FN3311-2300-99-C16-R55LINE FLTR 520/300VAC 2.3KA CHAS |
3,343 |
|
Datasheet | FN 3311 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300 V | 520 V | 2.3 kA | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FMAC-0956-H312ILINE FILTER 480/520VAC 250A CHAS |
3,115 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 250 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 300µH |
|
800 AHV D FPLINE FILTER 800A CHASSIS MOUNT |
2,218 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 800 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
1000 AHV D FPLINE FILTER 1KA CHASSIS MOUNT |
4,061 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 1 kA | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
700 AHV D FPLINE FILTER 700A CHASSIS MOUNT |
4,651 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 700 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FMAC-0957-H650LINE FILTER 480/520VAC 550A CHAS |
1,697 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 550 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Post | 200µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.