Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AMI-27B-1-3LINE FILTER 250VAC 1A CHASS MNT |
1,821 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 44mH |
|
AMI-27A-3-3LINE FILTER 250VAC 3A CHASS MNT |
4,682 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 19.6mH |
|
AMI-28A-6-1LINE FILTER 250VAC 6A CHASS MNT |
4,947 |
|
Datasheet | AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 7.91mH |
|
AMI-28A-3-3LINE FILTER 250VAC 3A CHASS MNT |
1,691 |
|
Datasheet | AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 9.96mH |
|
AMI-28B-3-3LINE FILTER 250VAC 3A CHASS MNT |
4,613 |
|
Datasheet | AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 9.96mH |
|
AMI-27B-3-3LINE FILTER 250VAC 3A CHASS MNT |
4,991 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 19.6mH |
|
AMI-27B-6-1LINE FILTER 250VAC 6A CHASS MNT |
2,118 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 15.6mH |
|
VFM-03-DINLINE FILTER 80VDC 3A DIN RAIL |
2,617 |
|
Datasheet | VFM-03 | Tray | Not For New Designs | DC | Single Stage | 80V | - | - | - | 3 A | - | General Purpose | - | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
AMI-M11R-7M-10-B-2LINE FILTER 250VAC 10A CHASS MNT |
1,733 |
|
Datasheet | AMI-M11R | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 7.13mH |
|
FMAB-N6PI-1046LINE FLTR 277/400VDC 277VAC CHAS |
3,812 |
|
Datasheet | FMAB | Box | Active | Single Phase | Single Stage | 277V, 400V | 277V | - | - | 10 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
AH-03LINE FILTER 110V/250VAC 3A CHASS |
4,864 |
|
Datasheet | AH | Box | Obsolete | Single Phase | Two Stage | - | 110V, 250V | - | - | 3 A | 50/60Hz | General Purpose | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FMAB-N7PH-0346LINE FLTR 277/400VDC 277VAC CHAS |
3,883 |
|
Datasheet | FMAB | Box | Active | Single Phase | Single Stage | 277V, 400V | 277V | - | - | 3 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
AH-L10LINE FILTER 110V/250VAC 10A CHAS |
3,824 |
|
Datasheet | AHL | Box | Obsolete | Single Phase | Two Stage | - | 110V, 250V | - | - | 10 A | 50/60Hz | General Purpose | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
A6-10ELINE FILTER, 250VAC, 6A, CHASSIS |
2,470 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AMI-M11H-6-30-ALINE FILTER 250VAC 30A CHASS MNT |
3,878 |
|
Datasheet | AMI-M11H | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 1.45mH |
|
AMI-M11F-3-6-ALINE FILTER 250VAC 6A CHASS MNT |
2,980 |
|
Datasheet | AMI-M11F | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Wire Leads | 18.5mH |
|
AMI-M12S-7-10-B-1LINE FILTER 250VAC 10A CHASS MNT |
2,269 |
|
Datasheet | AMI-M12S | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 990µH |
|
AMI-M11UA-1-16-CLINE FILTER 250VAC 16A CHASS MNT |
1,405 |
|
Datasheet | AMI-M11UA | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 540µH |
|
|
20DKBG5LINE FILTER 115V/250VAC 20A CHAS |
3,219 |
|
Datasheet | DK | Box | Active | Single Phase | Single Stage | - | 115V, 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.4mH |
|
AMI-M11O-6-30-BLINE FILTER 250VAC 30A CHASS MNT |
2,880 |
|
Datasheet | AMI-M11O | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 900µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.