Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
F1200BB01LINE FILTER 250VAC 1A CHASS MNT |
3,872 |
|
Datasheet | F1200 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
F1200BB06LINE FILTER 250VAC 6A CHASS MNT |
4,154 |
|
Datasheet | F1200 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
FLLE2001APMDLINE FILTER 300VAC/VDC 1A CHASS |
4,156 |
|
Datasheet | FLLE2-P | Bulk | Last Time Buy | Single Phase | Single Stage | 300V | 300V | - | - | 1 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 12mH |
|
FIHMA06C1FWMED FILTER 6A,CHASSIS,FAST-ON,WI |
3,320 |
|
Datasheet | - | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Medical | EN, UL | -40°C ~ 110°C | Chassis Mount | Quick Connect | 1.4mH |
|
FN2030BZ-1-06LINE FILTER 250VAC/VDC 1A CHASS |
3,130 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 1 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 20mH |
|
|
10DWCG5LINE FILTER 115V/250VAC 10A CHAS |
4,689 |
|
Datasheet | DW | Box | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | L1 - 1.2mH, L2 - 40mH |
|
FLLE2001APDDLINE FILTER 300VAC/VDC 1A CHASS |
1,058 |
|
Datasheet | FLLE2-P | Bulk | Last Time Buy | Single Phase | Single Stage | 300V | 300V | - | - | 1 A | 50/60Hz | General Purpose | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 12mH |
|
AHM-L03LINE FILTER 250VAC 3A CHASS MNT |
2,224 |
|
Datasheet | AHML | Box | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 3 A | 50/60Hz | Medical | CE, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
AMI-M12E-3-3-ALINE FILTER 250VAC 3A CHASS MNT |
2,946 |
|
Datasheet | AMI-M12E | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Wire Leads | 32.18mH |
|
|
FN2060B-1-06LINE FILTER 250VAC 1A CHASS MNT |
3,057 |
|
Datasheet | FN 2060 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 12mH |
|
FLLE2001AQMDLINE FILTER 300VAC/VDC 1A CHASS |
1,449 |
|
Datasheet | FLLE2-Q | Bulk | Last Time Buy | Single Phase | Single Stage | 300V | 300V | - | - | 1 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 12mH |
|
|
F1299BB10LINE FILTER 250VAC 10A CHASS MNT |
1,075 |
|
Datasheet | F1299 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Wire Leads | - |
|
|
F1200AA06LINE FILTER 250VAC 6A CHASS MNT |
4,026 |
|
Datasheet | F1200 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - |
|
3-143-596LINE FILTER 250VAC 1A CHASS MNT |
3,907 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | 50/60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FN2030-4-07LINE FILTER 250VAC/VDC 4A CHASS |
2,458 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 4 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 14mH |
|
FN2030Z-4-06LINE FILTER 250VAC/VDC 4A CHASS |
3,571 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 4 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 14mH |
|
RSEN-2003LLINE FILTER 250VAC/VDC 3A CHASS |
1,479 |
|
Datasheet | RSEN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
AMI-M11E-1-6-D-1LINE FILTER 250VAC 6A CHASS MNT |
3,682 |
|
Datasheet | AMI-M11E | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 3.45mH |
|
|
F1299BB03LINE FILTER 250VAC 3A CHASS MNT |
4,974 |
|
Datasheet | F1299 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Wire Leads | - |
|
F1200BB03LINE FILTER 250VAC 3A CHASS MNT |
4,823 |
|
Datasheet | F1200 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.