| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EAC-20-472-DLINE FILTER 250VAC/VDC 20A DIN |
2,388 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAC-20-681-DLINE FILTER 250VAC/VDC 20A DIN |
4,265 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
20DRPS4(D)LINE FILTER 250VAC 20A CHASS MNT |
1,162 |
|
Datasheet | DRP | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 500µH |
|
GTX-2200-Y0XLINE FLTR 560VDC 250VAC 20A CHAS |
4,015 |
|
Datasheet | GTX | Box | Active | Single Phase | Single Stage | 560V | 250V | - | - | 20 A | 50/60Hz | General Purpose | cUL, TUV, UL | -25°C ~ 55°C | Chassis Mount | Terminal Block | - |
|
M6-11FINTERCONNECT |
0 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
30DRPS4(D)LINE FILTER 250VAC 30A CHASS MNT |
4,895 |
|
Datasheet | DRP | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 120µH |
|
AMI-27A-16-1LINE FILTER 250VAC 16A CHASS MNT |
4,714 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 5.6mH |
|
EAP-10-000-DLINE FILTER 250VAC/VDC 10A DIN |
3,884 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-101-DLINE FILTER 250VAC/VDC 10A DIN |
4,280 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-102-DLINE FILTER 250VAC/VDC 10A DIN |
4,750 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-221-DLINE FILTER 250VAC/VDC 10A DIN |
1,908 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-222-DLINE FILTER 250VAC/VDC 10A DIN |
2,293 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-331-DLINE FILTER 250VAC/VDC 10A DIN |
4,740 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-332-DLINE FILTER 250VAC/VDC 10A DIN |
3,821 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-471-DLINE FILTER 250VAC/VDC 10A DIN |
3,888 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-472-DLINE FILTER 250VAC/VDC 10A DIN |
2,976 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAP-10-681-DLINE FILTER 250VAC/VDC 10A DIN |
2,215 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
|
F1250DD20LINE FILTER 250VAC 20A CHASS MNT |
1,148 |
|
Datasheet | F1250 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Threaded Post (8-32) | - |
|
5500.2611.01LINE FILTER 250VAC 3A CHASS MNT |
2,098 |
|
Datasheet | FMBB NEO | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | 9.8mH |
|
GTX-2160-Y0XLINE FLTR 560VDC 250VAC 16A CHAS |
2,044 |
|
Datasheet | GTX | Box | Active | Single Phase | Single Stage | 560V | 250V | - | - | 16 A | 50/60Hz | General Purpose | cUL, TUV, UL | -25°C ~ 55°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.