Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
STFE200-24LLINE FILTER 240VAC 20A DIN RAIL |
1,126 |
|
Datasheet | STFE | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 20 A | 47Hz, 63Hz | General Purpose | CE, cURus | -40°C ~ 50°C | DIN Rail | Terminal Block | - |
|
|
FN2200-1500-99LINE FILTER 1200VDC 1.5KA CHASS |
1,958 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1.5 kA | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN351H-180-36LINE FILTER 180A CHASSIS MOUNT |
3,715 |
|
Datasheet | FN 351 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 180 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2210-2300-99-R5LINE FILTER 1000VDC 2.3KA CHASS |
2,246 |
|
Datasheet | FN 2210 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 2.3 kA | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FMAC-0955-H212ILINE FILTER 480/520VAC 180A CHAS |
2,854 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 180 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 400µH |
|
FMAD-0955-H210LINE FILTER 277/480VAC 180A CHAS |
3,701 |
|
Datasheet | FMAD | Bulk | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 180 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 250µH |
|
FMAC-0956-H310LINE FILTER 480/520VAC 250A CHAS |
2,532 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 250 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 300µH |
|
FMAD-0956-H310LINE FILTER 277/480VAC 250A CHAS |
3,097 |
|
Datasheet | FMAD | Bag | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 250 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 200µH |
|
FN2200B-2300-99LINE FILTER 1200VDC 2.3KA CHASS |
4,851 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 2.3 kA | DC | Photovoltaic Inverter | cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359-1000-99LINE FILTER 1KA CHASSIS MOUNT |
2,360 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 1 kA | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359HV-1600-99LINE FILTER 1.6KA CHASSIS MOUNT |
3,696 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 1.6 kA | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
5500.2640.01LINE FILTER 125V/250VAC 1A CHASS |
4,248 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 1 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FN402B-1-02LINE FILTER 250VAC 1A TH |
1,484 |
|
Datasheet | FN 402 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 10mH |
|
5500.2651.04LINE FILTER 125V/250VAC 3A CHASS |
3,819 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
5500.2641.01LINE FILTER 125V/250VAC 3A CHASS |
3,404 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
10IHE1LINE FLTR 120/250VAC 10A PANEL |
3,283 |
|
Datasheet | IH, Corcom | Bulk | Active | Single Phase | Single Stage | - | 120V, 250V | 4000 V | 1500 V | 10 A | 50Hz ~ 60Hz | Medical | CSA, UL, VDE | -10°C ~ 40°C | Panel Mount | Quick Connect | - |
|
5500.2079LINE FILTER 125V/250VAC 4A CHASS |
4,389 |
|
Datasheet | FMLB-41 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 4 A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
5500.2100LINE FILTER 125V/250VAC 6A CHASS |
3,433 |
|
Datasheet | FMW-41 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 6 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
5500.2631.04LINE FILTER 125V/250VAC 3A CHASS |
2,094 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
10EK3LINE FILTER 250VAC 10A CHASS MNT |
3,576 |
|
Datasheet | K | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 495µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.