Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
40KEHD10AFPDLINE FILTER 440VAC 40A CHASS MNT |
3,480 |
|
Datasheet | KEH | Bulk | Active | Three Phase (Delta) | Two Stage | - | 440V | - | - | 40 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
20KEVD10BFPWLINE FILTER 520VAC 20A CHASS MNT |
2,177 |
|
Datasheet | KEV | Bulk | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
55KEVD10ABSWLINE FILTER 440VAC 55A CHASS MNT |
3,445 |
|
Datasheet | KEV-BS | Bulk | Active | Three Phase (Wye) | Two Stage | - | 440V | - | - | 55 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
36KEPS10BFPWLINE FILTER 520VAC 36A CHASS MNT |
2,999 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 36 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
50KEPS10AFPWLINE FILTER 440VAC 50A CHASS MNT |
4,409 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 50 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
25 AHV D FPLINE FILTER 125A CHASSIS MOUNT |
2,771 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 125 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
|
55KEHD10BBSDLINE FILTER 520VAC 55A CHASS MNT |
1,696 |
|
Datasheet | KEH-BS | Bulk | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 55 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
40KEVD10AFPWLINE FILTER 440VAC 40A CHASS MNT |
1,581 |
|
Datasheet | KEV | Bulk | Active | Three Phase (Wye) | Two Stage | - | 440V | - | - | 40 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
50KEMS10BFPDLINE FILTER 520VAC 50A CHASS MNT |
2,099 |
|
Datasheet | KEM | Bulk | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 50 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
55KEVD10BBSWLINE FILTER 520VAC 55A CHASS MNT |
1,143 |
|
Datasheet | KEV-BS | Bulk | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 55 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
50KEPS10BFPWLINE FILTER 520VAC 50A CHASS MNT |
2,065 |
|
Datasheet | KEP | Bulk | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 50 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
50KEMS10AFPDHMLINE FILTER 440VAC 50A CHASS MNT |
3,027 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 50 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
40 AHV S FPLINE FILTER 40A CHASSIS MOUNT |
4,225 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 40 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FN3288HVIT-50-53-C43-R60LINE FILTER 760VAC 50A CHASS MNT |
1,244 |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 50 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
30 AHV S BSLINE FILTER 30A CHASSIS MOUNT |
3,815 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 30 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
16 AHV D BSLINE FILTER 16A CHASSIS MOUNT |
1,400 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 16 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
20 AHV D BSLINE FILTER 20A CHASSIS MOUNT |
2,557 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 20 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
FMER-G62R-J017LINE FLTR 1200VDC 100A CHASS MNT |
3,268 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 100 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
16 AHV D FPLINE FILTER 6A CHASSIS MOUNT |
3,583 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 6 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
75KEMS10ABSDLINE FILTER 440VAC 75A CHASS MNT |
3,942 |
|
Datasheet | KEM-BS | Bulk | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 75 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.