Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN2520-20-07-C1111LINE FLTR 400VDC 277VAC 20A CHAS |
3,961 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 20 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Wire Leads | L1 - 2.4mH, L2 - 2.4mH |
|
B84742A0016R725LINE FILTER 250VAC/VDC 16A DIN |
3,817 |
|
Datasheet | B84742AxR725 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 16 A | 50/60Hz | Converter | UL | - | DIN Rail | Terminal Block | - |
|
FN2640-20-103-C11LINE FILTER 250VAC 20A CHASS MNT |
3,572 |
|
Datasheet | FN2640 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | DC ~ 60Hz | General Purpose | CE, CQC, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | IEC 320-C14, Terminal Block | 2.4mH |
|
RTEN-5006DLINE FILTER 500VAC/VDC 6A DIN |
1,621 |
|
Datasheet | RTEN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 6 A | - | General Purpose | EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
5500.2265LINE FILTER 125V/250VAC 3A DIN |
2,295 |
|
Datasheet | FMBB RAIL | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 3 A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | DIN Rail | Terminal Block | 12mH |
|
FN2660-20-05-C0909LINE FILTER 250VAC 20A CHASS MNT |
3,076 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C14, Quick Connect | L1 - 2.4mH, L2 - 2.4mH |
|
F1400BB06LINE FILTER 250VAC 6A CHASS MNT |
3,138 |
|
Datasheet | F1400 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
FN2660-16-07-C0909LINE FILTER 250VAC 16A CHASS MNT |
1,363 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C14, Wire Leads | L1 - 4mH, L2 - 4mH |
|
FN2520-15-103-C1111LINE FLTR 400VDC 277VAC 15A CHAS |
3,938 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 15 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Terminal Block | L1 - 4mH, L2 - 4mH |
|
FN2415B-6-29LINE FILTER 250VAC 6A CHASS MNT |
4,302 |
|
Datasheet | FN 2415 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2520-20-08-C1111LINE FLTR 400VDC 277VAC 20A CHAS |
2,597 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 20 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M4) | L1 - 2.4mH, L2 - 2.4mH |
|
FN2660-20-07-C0909LINE FILTER 250VAC 20A CHASS MNT |
1,682 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C14, Wire Leads | L1 - 2.4mH, L2 - 2.4mH |
|
FN2660-15-103-C0909LINE FILTER 250VAC 15A CHASS MNT |
2,785 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 15 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C14, Terminal Block | L1 - 4mH, L2 - 4mH |
|
FN2660-16-08-C0909LINE FILTER 250VAC 16A CHASS MNT |
3,320 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C20, Threaded Post (M4) | L1 - 4mH, L2 - 4mH |
|
5500.2606.01LINE FILTER 125V/250VAC 20A CHAS |
1,465 |
|
Datasheet | FMBB NEO | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 20 A | - | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
|
FN2520-25-07-C1111LINE FLTR 400VDC 277VAC 25A CHAS |
2,558 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 25 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Wire Leads | L1 - 1.5mH, L2 - 1.5mH |
|
FN2500-32-103-C13LINE FLTR 400VDC 277VAC 32A CHAS |
2,458 |
|
Datasheet | FN2500 | Bulk | Active | Single Phase | Single Stage | 400V | 277V | - | - | 32 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | 1.5mH |
|
FN2660-20-08-C0909LINE FILTER 250VAC 20A CHASS MNT |
1,830 |
|
Datasheet | FN2660 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | DC ~ 60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | IEC 320-C20, Threaded Post (M4) | L1 - 2.4mH, L2 - 2.4mH |
|
FN2520-25-08-C1111LINE FLTR 400VDC 277VAC 25A CHAS |
4,477 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 25 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M4) | L1 - 1.5mH, L2 - 1.5mH |
|
FN2520-20-103-C1111LINE FLTR 400VDC 277VAC 20A CHAS |
2,119 |
|
Datasheet | FN2520 | Bulk | Active | Single Phase | Two Stage | 400V | 277V | - | - | 20 A | DC ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, UKCA, UR | -40°C ~ 85°C | Chassis Mount | Terminal Block | L1 - 2.4mH, L2 - 2.4mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.