Time Delay Relays
Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Relay Type | Function | Circuit | Delay Time | Contact Rating @ Voltage | Voltage - Supply | Termination Style | Timing Adjustment Method | Timing Initiate Method | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
7012ADRELAY TIME DELAY 50SEC 10A 240V |
2,470 |
|
Datasheet | 7000, AGASTAT | Bulk | Active | Panel Mount | Mechanical Relay | On-Delay | DPDT (2 Form C) | 5 Sec ~ 50 Sec | 10A @ 240VAC | 120VAC | Screw Terminal | Hand Dial | Input Voltage | - | - |
|
7012BDRELAY TIME DELAY 50SEC 10A 240V |
2,475 |
|
Datasheet | 7000, AGASTAT | Bulk | Active | Panel Mount | Mechanical Relay | On-Delay | DPDT (2 Form C) | 5 Sec ~ 50 Sec | 10A @ 240VAC | 240VAC | Screw Terminal | Hand Dial | Input Voltage | - | - |
|
H5S-YB4-XRELAY TIME DELAY 1 YEAR 3A 250V |
2,548 |
|
Datasheet | H5S | Bulk | Active | Panel Mount | Mechanical Relay | Programmable (Multi-Function) | SPST-NO (1 Form A) x 4 | 1 Min ~ 1 Year | 3A @ 250VAC | 100 ~ 240VAC | Screw Terminal | Up/Down Digit Keys | Input Voltage | - | - |
|
7014ACRELAY TIME DELAY 20SEC 10A 240V |
3,969 |
|
Datasheet | 7000, AGASTAT | Bulk | Active | Panel Mount | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 2 Sec ~ 20 Sec | 10A @ 240VAC | 120VAC | Screw Terminal | Hand Dial | Input Voltage | - | - |
|
55MFT-P8-CURELAY TIME DELAY 300HR 6A 250V |
3,418 |
|
Datasheet | 55MF | Box | Active | Socketable | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) x 2 | 0.05 Sec ~ 300 Hrs | 6A @ 250VAC/24VDC | 20 ~ 240VAC/DC | Plug In, 8 Pin (Octal) | Screwdriver Slot | Input Voltage | - | - |
|
FS146RELAY TIME DELAY 75 FPM CHAS MT |
4,182 |
|
Datasheet | FS100 | Bulk | Active | Chassis Mount | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | Fixed, 75 FPM | - | 24VAC | Wire Leads | Fixed | Input Voltage | - | - |
|
FS146RCRELAY TIME DELAY 75 FPM CHAS MT |
4,802 |
|
Datasheet | FS100 | Bulk | Active | Chassis Mount | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | Fixed, 75 FPM | - | 24VAC | Wire Leads | Fixed | Input Voltage | - | - |
|
FS126-45RELAY TIME DELAY 45FPM CHAS MT |
1,659 |
|
Datasheet | FS100 | Bulk | Active | Chassis Mount | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | Fixed, 45 FPM | - | 120VAC | Wire Leads | Fixed | Input Voltage | - | - |
|
SDS.5S220ARELAY TIME DELAY 0.5SEC DIN RAIL |
2,747 |
|
Datasheet | SDS | Box | Active | DIN Rail | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | Fixed, 0.5 Sec | 1A @ 110VAC | 220VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
55MFT-P11-CURELAY TIME DELAY 30HR 6A 250V |
3,761 |
|
Datasheet | 55MF | Box | Active | Socketable | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) x 2 | 0.05 Sec ~ 30 Hrs | 6A @ 250VAC/24VDC | 20 ~ 240VAC/DC | Plug In, 11 Pin (Octal) | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
FS126-60RELAY TIME DELAY 60FPM CHAS MT |
2,907 |
|
Datasheet | FS100 | Bulk | Active | Chassis Mount | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | Fixed, 60 FPM | - | 120VAC | Wire Leads | Fixed | Input Voltage | - | - |
|
|
QAS1S110ADLRELAY TIME DELAY 1 SEC CHAS MT |
3,366 |
|
Datasheet | QAS | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPDT (1 Form C) | Fixed, 1 Sec | - | 110VAC/DC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
|
H3FA-B-DC12RELAY TIME DELAY 60MIN 3A 250V |
1,425 |
|
Datasheet | H3FA | Box | Active | Through Hole | Mechanical Relay | On-Delay | DPST-NO/NC (1 Form A and B) | 0.6 Sec ~ 60 Min | 3A @ 250VAC | 12VDC | PC Pin | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
CT1S45RELAY TIME DELAY 1SEC 45SEC |
1,565 |
|
Datasheet | CT | Bulk | Active | Chassis Mount | Solid State Relay | Off-Delay, On-Delay | SPST-NO (1 Form A) | Fixed, 1 Sec, 45 Sec | - | 24VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
MSM190W6RELAY TIME DELAY 90SEC CHAS MT |
3,543 |
|
Datasheet | MSM | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 90 Sec | - | 12VDC | Wire Leads | Fixed | Input Voltage | - | - |
|
|
H3YN-21 DC100-110RELAY TIME DELAY 10HR 5A 250V |
4,026 |
|
Datasheet | H3YN | Bulk | Active | Socketable | Mechanical Relay | Programmable (Multi-Function) | DPDT (2 Form C) | 0.1 Min ~ 10 Hrs | 5A @ 250VAC | 100 ~ 110VDC | Plug In | Hand Dial | Input Voltage | - | - |
|
|
KSD1230RELAY TIME DELAY 10SEC CHAS MT |
4,017 |
|
Datasheet | KSD1 | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | 0.1 Sec ~ 10 Sec | - | 24VAC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage | - | - |
|
|
KSD1420RELAY TIME DELAY 10SEC CHAS MT |
4,460 |
|
Datasheet | KSD1 | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | 0.1 Sec ~ 10 Sec | - | 120VAC | Quick Connect - 0.250" (6.3mm) | External Resistor | Input Voltage | - | - |
|
TSD761120SRELAY TIME DELAY 120 SEC CHAS MT |
1,248 |
|
Datasheet | TSD | Bulk | Active | Chassis Mount | Solid State Relay | Off-Delay | SPST-NO (1 Form A) | Fixed, 120 Sec | - | 230VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
ATS-C120RELAY TIME DELAY 16A 240V |
2,856 |
|
Datasheet | ATS | Box | Active | DIN Rail | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) | 1 Sec ~ 59 Sec | 16A @ 240VAC | 110 ~ 240VAC | Screw Terminal | Up/Down Digit Keys | Input Voltage | - | - |
Frequently Asked Questions
What are Time Delay Relays components used for?
Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Time Delay Relays part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.