Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DS1-F08LINE FILTER 250VAC/VDC 8A CHASS |
3,336 |
|
Datasheet | DS1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 8 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
|
3-1609090-9LINE FILTER 250VAC 16A CHASS MNT |
1,147 |
|
Datasheet | WG | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect, Threaded Post (M8) | 1.2mH |
|
IR3-N03C2HLINE FLTR 250VAC/VDC 3A PANEL |
3,092 |
|
Datasheet | IR3 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50 ~ 60Hz | Medical | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
IR3-N03CDHLINE FLTR 250VAC/VDC 3A PANEL |
2,744 |
|
Datasheet | IR3 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50 ~ 60Hz | Medical | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
ES1-F08LINE FILTER 250VAC/VDC 8A CHASS |
4,945 |
|
Datasheet | ES1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 8 A | 50 ~ 60Hz | General Purpose | CQC, CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
AMI-22B-6-1LINE FILTER 250VAC 6A CHASS MNT |
0 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1mH |
|
DS1-F10LINE FILTER 250VAC/VDC 10A CHASS |
2,148 |
|
Datasheet | DS1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FMAD-34SZ-0642.HPLINE FILTER 300V/520VAC 6A CHASS |
1,893 |
|
Datasheet | FMAD CP | Bulk | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 6 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAD-36SZ-0642.HPLINE FILTER 300V/520VAC 6A CHASS |
4,756 |
|
Datasheet | FMAD CP | Bulk | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 6 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
IR3-N06C2HLINE FLTR 250VAC/VDC 6A PANEL |
2,240 |
|
Datasheet | IR3 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | Medical | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
IR3-N06CDHLINE FLTR 250VAC/VDC 6A PANEL |
2,583 |
|
Datasheet | IR3 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | Medical | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
IR3-N10C2HLINE FLTR 250VAC/VDC 10A PANEL |
1,234 |
|
Datasheet | IR3 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | Medical | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
AMI-M11K-7-5-B-2LINE FILTER 250VAC 5A CHASS MNT |
2,789 |
|
Datasheet | AMI-M11K | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 5 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 516µH |
|
ES1-F10LINE FILTER 250VAC/VDC 10A CHASS |
2,133 |
|
Datasheet | ES1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CQC, CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
AMI-22B-10-1LINE FILTER 250VAC 10A CHASS MNT |
1,341 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
AMI-M11K-7-5-B-1LINE FILTER 250VAC 5A CHASS MNT |
4,134 |
|
Datasheet | AMI-M11K | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 5 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 516µH |
|
AMI-M11K-7-10-B-2LINE FILTER 250VAC 10A CHASS MNT |
1,851 |
|
Datasheet | AMI-M11K | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 495µH |
|
3-134-822LINE FILTER 250VAC 3A CHASS MNT |
1,103 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | - | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
AMI-M12Z-1-3-BLINE FILTER 250VAC 3A CHASS MNT |
3,254 |
|
Datasheet | AMI-M12Z | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.03mH |
|
AMI-22B-12-1LINE FILTER 250VAC 12A CHASS MNT |
2,213 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.