Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
6VAQ8FLINE FILTER 250VAC 6A CHASS MNT |
2,899 |
|
Datasheet | AQ | Bulk | Obsolete | Single Phase | Three Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
FN258-42-07LINE FILTER 42A CHASSIS MOUNT |
4,768 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 42 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
1609989-6LINE FILTER 75A CHASSIS MOUNT |
1,847 |
|
Datasheet | BCF | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 75 A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | - |
|
TB6-5080D3DGLINE FILTER 80A CHASSIS MOUNT |
3,772 |
|
Datasheet | TB6-2,5 G/H | Box | Active | Three Phase (Delta) | Two Stage | - | - | 290 V | 500 V | 80 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO, UL, UR | - | Chassis Mount | Terminal Block | - |
|
FN352Z-20-29LINE FILTER 250VAC 20A CHASS MNT |
1,424 |
|
Datasheet | FN 352Z | Tray | Obsolete | Single Phase | Three Stage | - | 250V | - | - | 20 A | DC ~ 400Hz | General Purpose | UR | -25°C ~ 85°C | Chassis Mount | Terminal Block | 3.5mH |
|
TB6-B150LASLINE FILTER 150A CHASSIS MOUNT |
4,258 |
|
Datasheet | TB6-B | Box | Active | Three Phase (Delta) | Single Stage | - | - | 254 V | 440 V | 150 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
55BCF10RLINE FILTER 55A CHASSIS MOUNT |
1,733 |
|
Datasheet | BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 55 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 1.8mH |
|
75BCF10RLINE FILTER 75A CHASSIS MOUNT |
3,270 |
|
Datasheet | BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 75 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 1.06mH |
|
FN258HV-42-33LINE FILTER 42A CHASSIS MOUNT |
4,946 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 42 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
55BCF6RLINE FILTER 55A CHASSIS MOUNT |
4,297 |
|
Datasheet | BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 55 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.8mH |
|
FN258-55-07LINE FILTER 55A CHASSIS MOUNT |
1,985 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 55 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAC-0934-5012ILINE FILTER 480V/520VAC 50A CHAS |
4,154 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 50 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
FN510-12-29LINE FILTER 12A CHASSIS MOUNT |
3,288 |
|
Datasheet | FN 510 | Tray | Obsolete | Three Phase (Delta) | - | - | - | 288 V | 500 V | 12 A | - | General Purpose | - | -25°C ~ 70°C | Chassis Mount | Terminal Block | - |
|
F2780Y001L-004LINE FILTER 100VDC 1A CHASS MNT |
1,259 |
|
Datasheet | F2780Y | Box | Active | Single Phase | Two Stage | 100V | - | - | - | 1 A | - | General Purpose | cUL, UL | -25°C ~ 85°C | Chassis Mount | Wire Leads | - |
|
TB4-100GRLINE FILTER 100A CHASSIS MOUNT |
4,472 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 100 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN258P-55-34LINE FILTER 55A CHASSIS MOUNT |
1,813 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 55 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
45AYP6CLINE FILTER 45A CHASSIS MOUNT |
3,606 |
|
Datasheet | A | Bulk | Last Time Buy | Three Phase (Wye) | Two Stage | - | - | 250 V | 440 V | 45 A | 50/60Hz | General Purpose | CSA, UL | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 1.1mH |
|
TB6-5100D6DHLINE FILTER 100A CHASSIS MOUNT |
3,590 |
|
Datasheet | TB6-2,5 G/H | Box | Active | Three Phase (Delta) | Two Stage | - | - | 290 V | 500 V | 100 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO, UL, UR | - | Chassis Mount | Terminal Block | - |
|
TB6-5060D3DHLINE FILTER 60A CHASSIS MOUNT |
2,045 |
|
Datasheet | TB6-2,5 G/H | Box | Active | Three Phase (Delta) | Two Stage | - | - | 290 V | 500 V | 60 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO, UL, UR | - | Chassis Mount | Terminal Block | - |
|
TB4-120GRLINE FILTER 120A CHASSIS MOUNT |
3,810 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 120 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.