Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TB6-B400LBSLINE FILTER 400A CHASSIS MOUNT |
1,628 |
|
Datasheet | TB6-B | Box | Active | Three Phase (Delta) | Two Stage | - | - | 254 V | 440 V | 400 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN258-130-35LINE FILTER 130A CHASSIS MOUNT |
4,499 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 130 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
LF-260NLINE FILTER 250VAC/VDC 60A CHASS |
1,909 |
|
Datasheet | LF | Tray | Obsolete | Single Phase | Two Stage | 250V | 250V | - | - | 60 A | - | General Purpose | - | -20°C ~ 55°C | Chassis Mount | Threaded Post (M6) | - |
|
FLLD4160ATHT7LINE FILTER 160A CHASSIS MOUNT |
4,151 |
|
Datasheet | FLLD3 | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 305 V | 530 V | 160 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
6609070-8LINE FILTER 110A CHASSIS MOUNT |
1,401 |
|
Datasheet | FCD | Box | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 110 A | 50 ~ 60Hz | Regenerative Motor Drive | UL | -10°C ~ 40°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
2-6609974-0LINE FILTER 150A CHASSIS MOUNT |
3,122 |
|
Datasheet | FCD | Box | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 150 A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
FN258HVIT-130-35LINE FILTER 130A CHASSIS MOUNT |
1,672 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 130 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
250APS12LLINE FLTR 520VAC 250A CHASS MNT |
1,175 |
|
Datasheet | APS | Bulk | Active | Three Phase (Delta) | Three Stage | - | 520V | - | - | 250 A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
FN356-100-28LINE FILTER 100A CHASSIS MOUNT |
2,256 |
|
Datasheet | FN 356 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 250 V | 440 V | 100 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
FN258HV-130-35LINE FILTER 130A CHASSIS MOUNT |
1,827 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 130 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TB4-400GRLINE FILTER 400A CHASSIS MOUNT |
1,368 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 400 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FLLD4200ATHT7LINE FILTER 200A CHASSIS MOUNT |
2,356 |
|
Datasheet | FLLD3 | Bulk | Active | Three Phase (Wye) | Single Stage | - | - | 305 V | 530 V | 200 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
LF-350LINE FILTER 250VAC/VDC 50A CHASS |
1,054 |
|
Datasheet | LF | Bulk | Active | Three Phase (Delta) | Two Stage | 250V | 250V | - | - | 50 A | - | General Purpose | - | -20°C ~ 45°C | Chassis Mount | Threaded Post (M4) | - |
|
6609067-7LINE FILTER 150A CHASSIS MOUNT |
4,360 |
|
Datasheet | AYC | Box | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 150 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
1-6609070-2LINE FILTER 230A CHASSIS MOUNT |
4,698 |
|
Datasheet | FCD | Bulk | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 230 A | 50/60Hz | General Purpose | UL | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
FMBC-0964-H110LINE FLTR 480VAC 115A CHASS MNT |
1,408 |
|
Datasheet | FMBC BOOK STYLE | Bulk | Obsolete | Three Phase (Delta) | Two Stage | - | 480V | - | - | 115 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 700µH, L2 - 200µH |
|
TB6-4250BC62LINE FILTER 250A CHASSIS MOUNT |
3,949 |
|
Datasheet | TB6-2/4 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 250 V | 440 V | 250 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
TB4-500GRLINE FILTER 500A CHASSIS MOUNT |
2,522 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 500 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TB4-250HRLINE FILTER 250A CHASSIS MOUNT |
2,590 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 250 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-6609974-3LINE FILTER 150A CHASSIS MOUNT |
1,993 |
|
Datasheet | FCD | Bag | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 150 A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.