| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
180BCF10RLINE FILTER 180A CHASSIS MOUNT |
3,952 |
|
Datasheet | BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 180 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 340µH |
|
|
180BCF6RLINE FILTER 180A CHASSIS MOUNT |
4,779 |
|
Datasheet | BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 180 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 340µH |
|
6609977-6LINE FILTER 180A CHASSIS MOUNT |
3,041 |
|
Datasheet | AYC | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 180 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
TB6-4300BC62LINE FILTER 300A CHASSIS MOUNT |
3,761 |
|
Datasheet | TB6-2/4 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 250 V | 440 V | 300 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
TB4-400HRLINE FILTER 400A CHASSIS MOUNT |
2,239 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 400 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
400APS12PLINE FLTR 690VAC 400A CHASS MNT |
1,202 |
|
Datasheet | APS | Bulk | Active | Three Phase (Delta) | Three Stage | - | 690V | - | - | 400 A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
FMBC-A91V-J812LINE FILTER 480/520VAC 180A CHAS |
2,911 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 180 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 400µH, L2 - 31µH |
|
FLLD31K0APVI1LINE FILTER 520VAC 1KA CHASS MNT |
2,842 |
|
Datasheet | FLLD3-PV | Bulk | Last Time Buy | Three Phase (Delta) | - | - | 520V | - | - | 1 kA | 50/60Hz | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FN258-250-07LINE FILTER 250A CHASSIS MOUNT |
4,476 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 250 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-6609974-6LINE FILTER 230A CHASSIS MOUNT |
4,854 |
|
Datasheet | FCD | Box | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 230 A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
600APH12LLINE FLTR 520VAC 600A CHASS MNT |
1,843 |
|
Datasheet | APH | Box | Active | Three Phase (Delta) | Three Stage | - | 520V | - | - | 600 A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
TB4-500HRLINE FILTER 500A CHASSIS MOUNT |
1,653 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 500 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TB6-4400BC62LINE FILTER 400A CHASSIS MOUNT |
1,737 |
|
Datasheet | TB6-2/4 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 250 V | 440 V | 400 A | 50 ~ 60Hz | General Purpose | CE, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
TB4-600HRLINE FILTER 600A CHASSIS MOUNT |
2,727 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 600 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TB4-600GRLINE FILTER 600A CHASSIS MOUNT |
3,423 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 600 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
400APH12PLINE FLTR 690VAC 400A CHASS MNT |
4,507 |
|
Datasheet | APH | Bulk | Discontinued at Digi-Key | Three Phase (Delta) | Three Stage | - | 690V | - | - | 400 A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
TB4-700GRLINE FILTER 700A CHASSIS MOUNT |
3,934 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 700 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FLLD31K6APVI1LINE FLTR 520VAC 1.6KA CHASS MNT |
1,849 |
|
Datasheet | FLLD3-PV | Bulk | Active | Three Phase (Delta) | - | - | 520V | - | - | 1.6 kA | 50/60Hz | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FMER-G62W-S557LINE FILTER 1200VDC 1.5KA CHASS |
4,404 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1.5 kA | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
TB4-700HRLINE FILTER 700A CHASSIS MOUNT |
1,219 |
|
Datasheet | TB4 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 290 V | 500 V | 700 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.