| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
125KEMS6BFPDLINE FLTR 520VAC 125A CHASS MNT |
1,873 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 125 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10) | - |
|
|
200TDSS84LINE FLTR 480VAC 200A CHASS MNT |
2,700 |
|
Datasheet | TDS | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 200 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Quick Connect | 90µH |
|
B84312F0040B101LINE FILTER 0.1A CHASSIS MOUNT |
2,883 |
|
Datasheet | B84312 | Box | Active | Single Phase | Three Stage | - | - | 100 V | 100 V | 100 mA | - | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M6) | - |
|
3-138-329LINE FILTER 230A CHASSIS MOUNT |
1,316 |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 760 V | 230 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
125KEPS6BFPWLINE FLTR 520VAC 125A CHASS MNT |
4,932 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 125 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10) | - |
|
SF1917V1LINE FILTER ASSY |
3,710 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FN258-100-35LINE FILTER 100A CHASSIS MOUNT |
2,754 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
DG60-4FFLINE FILTER, 3-PHASE, 600VAC, 60 |
1,642 |
|
Datasheet | DG | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 350 V | 600 V | 60 A | 47Hz, 63Hz | General Purpose | cCSAus | - | Chassis Mount | Threaded Post (1/4-20) | - |
|
B86306A0074S000LINE FILTER 520VAC 74A CHASS MNT |
2,949 |
|
Datasheet | B86306 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 74 A | 50/60Hz | Converter | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | 460µH |
|
|
FLLE2250APXI1LINE FLTR 1200VDC 250A CHASS MNT |
4,819 |
|
Datasheet | FLLE2-PV | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 250 A | - | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3311-250-99-C28-R55LINE FILTER 250A CHASSIS MOUNT |
2,250 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 250 A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143D0120R127LINE FILTER 120A CHASSIS MOUNT |
3,792 |
|
Datasheet | B84143D | Bulk | Active | Three Phase (Delta) | - | - | - | - | - | 120 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-A91G-J012LINE FILTER 480/520VAC 100A CHAS |
3,210 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 100 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.2mH, L2 - 13µH |
|
FMAC-091G-H210LINE FLTR 480VAC 150A CHASS MNT |
3,675 |
|
Datasheet | FMAC ECO | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 150 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 480µH |
|
FN3288HV-125-35-C25-R65LINE FILTER 125A CHASSIS MOUNT |
3,745 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 125 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3311IT-250-99-C18-R5LINE FILTER 250A CHASSIS MOUNT |
2,699 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 250 A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
3-138-357LINE FILTER 230A CHASSIS MOUNT |
1,263 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 230 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
|
160TYT8-2LINE FILTER 520VAC CHASSIS MOUNT |
1,219 |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | - | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | L1 - 500µH, L2 - 6µH |
|
DE100-5FFLINE FILTER, 3-PHASE, 480VAC, 10 |
1,305 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AGPH12015LINE FILTER 120VAC 15A CHASS MNT |
1,868 |
|
Datasheet | - | Bulk | Active | Single Phase | - | - | 120V | - | - | 15 A | - | General Purpose | UL | - | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.