Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
FN5010-32-99 Schaffner EMC Inc.

FN5010-32-99

LINE FILTER 32A CHASSIS MOUNT

Schaffner EMC Inc.

2,228
Datasheet FN 5010 Tray Obsolete Three Phase (Delta) Single Stage - - 230 V 400 V 32 A - Inverters, Power Drive Systems - -25°C ~ 85°C Chassis Mount Terminal Block 2mH
FN3288HV-160-40-C25-R65 Schaffner EMC Inc.

FN3288HV-160-40-C25-R65

LINE FILTER 160A CHASSIS MOUNT

Schaffner EMC Inc.

3,729
Datasheet FN 3288 Bulk Active Three Phase (Delta) Two Stage - - 440 V 760 V 160 A DC ~ 60Hz Inverters, Power Drive Systems CE, ENEC, UKCA, UR -40°C ~ 100°C Chassis Mount Terminal Block -
B84144A0150R000 EPCOS - TDK Electronics

B84144A0150R000

LINE FILTER 440/250VAC 150A CHAS

EPCOS - TDK Electronics

2,959
Datasheet B84144 Bulk Active Three Phase (Wye) Single Stage - 440V, 250V 250 V 440 V 150 A 50 ~ 60Hz General Purpose UL - Chassis Mount Terminal Block, Threaded Post (M10) -
FTA-80-104-H Cosel USA, Inc.

FTA-80-104-H

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

2,611
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-104-S Cosel USA, Inc.

FTA-80-104-S

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

3,177
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-155-H Cosel USA, Inc.

FTA-80-155-H

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

3,052
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-223-H Cosel USA, Inc.

FTA-80-223-H

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

4,729
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-683-H Cosel USA, Inc.

FTA-80-683-H

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

1,491
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FN258L-130-35 Schaffner EMC Inc.

FN258L-130-35

LINE FILTER 130A CHASSIS MOUNT

Schaffner EMC Inc.

4,267
Datasheet FN 258 Tray Obsolete Three Phase (Delta) Two Stage - - 277 V 480 V 130 A DC ~ 60Hz Inverters, Power Drive Systems CSA, ENEC, UR -25°C ~ 100°C Chassis Mount Terminal Block -
B84320Z0010E047 EPCOS - TDK Electronics

B84320Z0010E047

LINE FILTER 0.1A CHASSIS MOUNT

EPCOS - TDK Electronics

3,862
Datasheet - Box Active Three Phase (Delta) Three Stage - - 15 V 15 V 100 mA - General Purpose - - Chassis Mount Threaded Post (M6) -
F3480T080 Curtis Industries

F3480T080

LINE FILTER 480VAC 80A CHASS MNT

Curtis Industries

1,511
Datasheet F3480 Box Active Three Phase (Delta) Two Stage - 480V - - 80 A 50/60Hz General Purpose CE, UR - Chassis Mount Terminal Block -
FTA-100-104-H Cosel USA, Inc.

FTA-100-104-H

LINE FLTR 500VAC 100A CHASS MNT

Cosel USA, Inc.

4,896
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 100 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-100-155-H Cosel USA, Inc.

FTA-100-155-H

LINE FLTR 500VAC 100A CHASS MNT

Cosel USA, Inc.

2,967
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 100 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-100-223-H Cosel USA, Inc.

FTA-100-223-H

LINE FLTR 500VAC 100A CHASS MNT

Cosel USA, Inc.

1,305
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 100 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-100-683-H Cosel USA, Inc.

FTA-100-683-H

LINE FLTR 500VAC 100A CHASS MNT

Cosel USA, Inc.

4,623
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 100 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
B84143V0010R230 EPCOS - TDK Electronics

B84143V0010R230

LINE FILTER 690V/400VAC 10A CHAS

EPCOS - TDK Electronics

2,201
Datasheet B84143V Box Active Three Phase (Delta) Single Stage - 690V, 400V - - 10 A 50/60Hz General Purpose cURus -25°C ~ 85°C Chassis Mount Terminal Block -
B84243A6180Z000 EPCOS - TDK Electronics

B84243A6180Z000

LINE FILTER 530/305VAC 180A CHAS

EPCOS - TDK Electronics

4,139
Datasheet B84243 Box Active Three Phase (Delta) Single Stage - 530V, 305V - - 180 A 50/60Hz Converter cUR, UR -25°C ~ 100°C Chassis Mount Terminal Block -
RTCN-5150 TDK-Lambda

RTCN-5150

LINE FILTER 500VAC/VDC 150A CHAS

TDK-Lambda

1,089
Datasheet RTCN Bulk Active Three Phase (Delta) Single Stage 500V 500V - - 150 A - General Purpose EN, UL -25°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-104-HS Cosel USA, Inc.

FTA-80-104-HS

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

4,031
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-80-155-HS Cosel USA, Inc.

FTA-80-155-HS

LINE FILTER 500VAC 80A CHASS MNT

Cosel USA, Inc.

3,886
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 80 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
Total 8635 Record«Prev1... 352353354355356357358359...432Next»
FAQ

Frequently Asked Questions

What are Power Line Filter Modules components used for?

Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Line Filter Modules part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Power Line Filter Modules?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top