Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMAC-0954-H112ILINE FILTER 480/520VAC 110A CHAS |
4,582 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 110 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 700µH |
|
RTEN-2080LINE FILTER 80A CHASSIS MOUNT |
3,405 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 80 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RSHN-2080LINE FILTER 250VAC/VDC 80A CHASS |
2,283 |
|
Datasheet | RSHN | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 80 A | - | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMCC-I93A-J834LINE FILTER 180A CHASSIS MOUNT |
4,197 |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 180 A | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
200KEPS6AFPWLINE FLTR 440VAC 200A CHASS MNT |
1,139 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 200 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10) | - |
|
FN5420-26-92-E0XXTLINE FILTER 26A CHASSIS MOUNT |
4,102 |
|
Datasheet | FN 5420 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 480 V | 530 V | 26 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus, UKCA | -40°C ~ 70°C | Chassis Mount | Terminal Block | 1.7mH |
|
B84142C0400S081LINE FLTR 1500VDC 600VAC CHAS |
4,096 |
|
Datasheet | B84142C | Box | Active | DC | Two Stage | 1500V (1.5kV) | 600V | - | - | 400 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
80AYC10BLINE FILTER 80A CHASSIS MOUNT |
3,176 |
|
Datasheet | AYC | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 80 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
B84143A0180R000LINE FILTER 480/275VAC 180A CHAS |
2,590 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 275V | 275 V | 480 V | 180 A | 50 ~ 60Hz | Inverters, Power Drive Systems | UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
FTA-150-104-SLINE FLTR 500VAC 150A CHASS MNT |
2,422 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-155-SLINE FLTR 500VAC 150A CHASS MNT |
3,339 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-223-SLINE FLTR 500VAC 150A CHASS MNT |
4,432 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-683-SLINE FLTR 500VAC 150A CHASS MNT |
3,143 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B86301U0400S000LINE FILTER 520VAC 400A |
1,419 |
|
Datasheet | B86301 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 400 A | 50/60Hz | General Purpose | cURus | -25°C ~ 100°C | - | Terminal Post | 13µH |
|
B86305L0390S000LINE FLTR 520VAC 390A CHASS MNT |
4,666 |
|
Datasheet | B86305 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 390 A | 50/60Hz | Converter | cURus | -25°C ~ 100°C | Chassis Mount | Terminal Block | 75µH |
|
B84144A0200R140LINE FILTER 200A CHASSIS MOUNT |
2,073 |
|
Datasheet | B84144 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 520 V | 300 V | 200 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN520-12-29LINE FILTER 12A CHASSIS MOUNT |
3,370 |
|
Datasheet | FN 520 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 288 V | 500 V | 12 A | - | Regenerative Motor Drive | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84143B0150S021LINE FILTER 760/440VAC 150A CHAS |
1,631 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | - | - | 150 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
B84142J0400S081LINE FLTR 1000VDC 600VAC CHAS |
1,047 |
|
Datasheet | B84142 | Box | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 400 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3310-400-99-R5LINE FLTR 520VAC 400A CHASS MNT |
3,341 |
|
Datasheet | FN 3310 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 400 A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.