| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FLLD3800APVI1LINE FLTR 520VAC 800A CHASS MNT |
1,920 |
|
Datasheet | FLLD3-PV | Bulk | Last Time Buy | Three Phase (Delta) | - | - | 520V | - | - | 800 A | 50/60Hz | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
RSHN-2150LINE FILTER 250VAC/VDC 150A CHAS |
3,199 |
|
Datasheet | RSHN | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 150 A | - | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143K0320S081LINE FILTER 760/440VAC 320A CHAS |
1,236 |
|
Datasheet | B84143K | Box | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | 760 V | 440 V | 320 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3840-380-99-C2835-R67LINE FILTER 380A CHASSIS MOUNT |
3,584 |
|
Datasheet | FN3840 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 380 A | 50/60Hz | Regenerative Motor Drive | CE, ENEC, UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3311-1000-99-C28-R55LINE FILTER 1KA CHASSIS MOUNT |
1,213 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 1 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
RTEN-5100J9J3-00LINE FILTER 100A CHASSIS MOUNT |
2,312 |
|
Datasheet | RTEN-J9J3-00 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 500 V | 500 V | 100 A | - | General Purpose | ENEC | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RTHN-5150LINE FILTER 500VAC/VDC 150A CHAS |
2,922 |
|
Datasheet | RTHN | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 150 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3311IT-1000-99-C18-R5LINE FILTER 1KA CHASSIS MOUNT |
2,674 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 1 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
F3480T160LINE FLTR 480VAC 160A CHASS MNT |
3,606 |
|
Datasheet | F3480 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 160 A | 50/60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - |
|
FN258L-250-07LINE FILTER 250A CHASSIS MOUNT |
1,009 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 250 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
400APH12LLINE FLTR 520VAC 400A CHASS MNT |
4,070 |
|
Datasheet | APH | Box | Active | Three Phase (Delta) | Three Stage | - | 520V | - | - | 400 A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
FN3268-180-40LINE FILTER 180A CHASSIS MOUNT |
1,227 |
|
Datasheet | FN 3268 | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 180 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
DE200-5FFLINE FILTER, 3-PHASE, 480VAC, 20 |
2,107 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FN3310HV-1000-99-R5LINE FILTER 1KA CHASSIS MOUNT |
1,818 |
|
Datasheet | FN 3310 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 1 kA | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143C0315S250LINE FILTER 315A CHASSIS MOUNT |
1,854 |
|
Datasheet | B84143C*S250 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 315 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FLLE21K0APVI1LINE FLTR 1200VDC 1KA CHASS MNT |
1,950 |
|
Datasheet | FLLE2-PV | Bulk | Last Time Buy | Single Phase | Single Stage | 1200V (1.2kV) | - | - | - | 1 kA | - | Photovoltaic Inverter | UL | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3280H-300-99LINE FILTER 300A CHASSIS MOUNT |
3,191 |
|
Datasheet | FN 3280 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 300 V | 520 V | 300 A | DC ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
FMER-G92V-Q057LINE FLTR 1200VDC 800A CHASS MNT |
1,103 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 800 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
F3480T185LINE FLTR 480VAC 185A CHASS MNT |
2,945 |
|
Datasheet | F3480 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 185 A | 50/60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - |
|
B84143B0400S081LINE FILTER 400A CHASSIS MOUNT |
2,414 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 440 V | 400 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Post | 130µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.