Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN5045-62-34LINE FILTER 62A CHASSIS MOUNT |
4,957 |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 62 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 850µH |
|
RTEN-2200LINE FILTER 200A CHASSIS MOUNT |
3,048 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 200 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
FMER-G92V-S057LINE FLTR 1200VDC 1KA CHASS MNT |
4,429 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1 kA | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
DG200-5FFLINE FILTER, 3-PHASE, 600VAC, 20 |
4,002 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FLLD31K0APZI1LINE FILTER 1KA CHASSIS MOUNT |
1,721 |
|
Datasheet | FLLD3 – PH | Bulk | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 1 kA | 50 ~ 60Hz | General Purpose | UL | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3280H-600-99LINE FILTER 600A CHASSIS MOUNT |
3,603 |
|
Datasheet | FN 3280 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 300 V | 520 V | 600 A | DC ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143C0400S250LINE FILTER 400A CHASSIS MOUNT |
3,850 |
|
Datasheet | B84143C*S250 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 400 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FN3359HV-320-99LINE FILTER 320A CHASSIS MOUNT |
3,443 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 320 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143K0600S081LINE FILTER 760/440VAC 600A CHAS |
4,664 |
|
Datasheet | B84143K | Box | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | 760 V | 440 V | 600 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
RTEN-2250LINE FILTER 250A CHASSIS MOUNT |
3,992 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 250 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143C0315S251LINE FILTER 315A CHASSIS MOUNT |
4,968 |
|
Datasheet | B84143C*S251 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 315 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
B84143B0600S021LINE FILTER 760/440VAC 600A CHAS |
3,866 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | - | - | 600 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
|
500TDSS84LINE FLTR 480VAC 500A CHASS MNT |
3,427 |
|
Datasheet | TDS | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 500 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Quick Connect | 3µH |
|
B84142C1600S081LINE FILTER 1500VDC 1.6KA CHASS |
4,537 |
|
Datasheet | B84142C | Bulk | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 1.6 kA | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
1000APS12PLINE FILTER 690VAC 1KA CHASS MNT |
3,406 |
|
Datasheet | APS | Box | Active | Three Phase (Delta) | Three Stage | - | 690V | - | - | 1 kA | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
RTEN-2300LINE FILTER 300A CHASSIS MOUNT |
2,416 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 300 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84142J1600S081LINE FLTR 1KVDC 600VAC 1.6KA CHA |
4,866 |
|
Datasheet | B84142 | Box | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 1.6 kA | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FMCC-I93E-Q054LINE FILTER 800A CHASSIS MOUNT |
4,082 |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 800 A | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post, Threaded Post (M12) | - |
|
FN3311-1500-99-C28-R55LINE FILTER 1.5KA CHASSIS MOUNT |
4,810 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 1.5 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84144B0600S120LINE FILTER 600A CHASSIS MOUNT |
2,805 |
|
Datasheet | B84144 | Bulk | Active | Three Phase (Wye) | Three Stage | - | - | 530 V | 305 V | 600 A | 50 ~ 60Hz | Converter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.