Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B84143V0045R127LINE FILTER 520VAC 45A CHASS MNT |
2,598 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 45 A | 50/60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
B84143V0064R231LINE FILTER 230V/400VAC 64A CHAS |
3,574 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | 230V, 400V | - | - | 64 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143V0040R230LINE FILTER 690V/400VAC 40A CHAS |
1,078 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | 690V, 400V | - | - | 40 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3270H-800-99LINE FILTER 800A CHASSIS MOUNT |
1,668 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 800 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3311IT-1500-99-C18-R5LINE FILTER 1.5KA CHASSIS MOUNT |
4,106 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 1.5 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
110AYC10BLINE FILTER 110A CHASSIS MOUNT |
2,529 |
|
Datasheet | AYC | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 110 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
600TDSS84LINE FLTR 480VAC 600A CHASS MNT |
3,324 |
|
Datasheet | TDS | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 600 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Quick Connect | 3µH |
|
B86305L0900S000LINE FLTR 520VAC 900A CHASS MNT |
4,036 |
|
Datasheet | B86305 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 900 A | 50/60Hz | Converter | cURus | -25°C ~ 100°C | Chassis Mount | Terminal Block | 34µH |
|
B84299D2160B001LINE FILTER 250VAC 16A CHASS MNT |
1,206 |
|
Datasheet | - | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M8) | - |
|
FN3310HV-1500-99-R5LINE FILTER 1.5KA CHASSIS MOUNT |
4,923 |
|
Datasheet | FN 3310 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 1.5 kA | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-1609979-7LINE FILTER 400A CHASSIS MOUNT |
3,999 |
|
Datasheet | CFN | Box | Active | Three Phase (Delta) | Three Stage | - | - | 277 V | 480 V | 400 A | 50/60Hz | Inverters, Power Drive Systems | UR | -10°C ~ 40°C | Chassis Mount | Terminal Post | - |
|
FMAC-0956-H350LINE FILTER 480/520VAC 250A CHAS |
4,224 |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 250 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 300µH |
|
FMCC-H93E-S052LINE FILTER 1KA CHASSIS MOUNT |
4,127 |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 1 kA | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post, Threaded Post (M12) | - |
|
TSD-400-136LINE FILTER 400A CHASSIS MOUNT |
2,960 |
|
Datasheet | TSD | Bulk | Active | Three Phase (Delta) | Three Stage | - | - | 500 V | 610 V | 400 A | 50/60Hz | Regenerative Motor Drive | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Post | - |
|
TSD-400-186LINE FILTER 400A CHASSIS MOUNT |
1,423 |
|
Datasheet | TSD | Bulk | Active | Three Phase (Delta) | Three Stage | - | - | 500 V | 610 V | 400 A | 50/60Hz | Regenerative Motor Drive | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Post | - |
|
TSD-400-105LINE FILTER 400A CHASSIS MOUNT |
1,232 |
|
Datasheet | TSD | Bulk | Active | Three Phase (Delta) | Three Stage | - | - | 500 V | 610 V | 400 A | 50/60Hz | Regenerative Motor Drive | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Post | - |
|
TSD-400-215LINE FILTER 400A CHASSIS MOUNT |
4,894 |
|
Datasheet | TSD | Bulk | Active | Three Phase (Delta) | Three Stage | - | - | 500 V | 610 V | 400 A | 50/60Hz | Regenerative Motor Drive | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Post | - |
|
FN351-180-36LINE FILTER 180A CHASSIS MOUNT |
3,776 |
|
Datasheet | FN 351 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 250 V | 440 V | 180 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
FMER-G92W-S557LINE FILTER 1200VDC 1.5KA CHASS |
3,195 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1.5 kA | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
500TYSS104LINE FILTER 480VAC CHASSIS MOUNT |
3,649 |
|
Datasheet | TYS | Box | Active | Three Phase (Wye) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Post | 3µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.